SYSTem Subsystem

SYSTem:FACTory

This command sets the IntelliFrame Mainframe settings (except the communication settings) to the factory default values. Table 3±16 lists the impacted commands and their factory default settings.

Table 3±16: Super Cooler factory default settings

Command

Settings

 

 

DISPlay[:WINDow]:TEXT:[DATA]

ªSYSTEM OKº

 

 

DISPlay[:WINDow]:TEXT:MARQuee

AUTO

 

 

STATus:OPERation:ENABle

0

 

 

STATus:OPERation:VXIInterrupt:ENABle

32767

 

 

STATus:OPERation:VXIMonitor:ENABle

32767

 

 

STATus:OPERation:VXITrigger:ENABle

32767

 

 

STATus:QUEStionable:BLOWer:ENABle

32767

 

 

STATus:QUEStionable:CURRent:ENABle

 

 

 

STATus:QUEStionable:CURRent:LIMit

32767

 

 

STATus:QUEStionable:ENABle

0

 

 

STATus:QUEStionable:FILTer:TINTerval

4000

 

 

STATus:QUEStionable:POWer:ENABle

32767

 

 

STATus:QUEStionable:POWer:LIMit

VX1410A: 925.0

 

VX1420A: 1000.0

 

 

STATus:QUEStionable:TEMPerature:ENABle

32767

 

 

STATus:QUEStionable:TEMPerature:LIMit

AMBient: 55

 

DELTaN: 10

 

 

STATus:QUEStionable:VOLTage:ENABle

32767

 

 

STATus:QUEStionable:VOLTage:PTR

32743

 

 

STATus:QUEue:ENABle

(±1999:1000)

 

 

SYSTem:ERRor:ENABle

(±1999:1000)

 

 

SYSTem:SYSReset

0

 

 

VXIMonitor:REPeat

0

 

 

VXIMonitor:TINTerval

10

 

 

*ESE

0

 

 

*PSC

0

 

 

*SRE

0

 

 

Syntax SYSTem:FACTory

VX1410A & VX1420A IntelliFrame Mainframe Instruction Manual

3±131