STATus Subsystem
STATus:OPERation:VXITrigger:CONDition?
Queries the contents of the VXI TTL Trigger Monitor Condition register. A value of one in a bit indicates the corresponding condition bit has transitioned from high to low. Unused bits always return a value of zero. The definition of the bits in this register can be found in STATus:OPERation:VXITrigger command.
The enhanced monitor latches the state of VXI TTL Trigger lines into a hardware register. This register cleared upon VXI Monitor initialization. This query returns the state of this register.
There is no command associated with this query.
Syntax | STTusOPERationVXITriggerCONDition | ||
Parameters |
|
|
|
Parameter |
| Query response | |
| Not applicable | <NR1> | |
Reset Value |
|
| |
Not Applicable |
| ||
Errors and Events | None |
|
|
Dependencies | None |
|
|
Examples | Query: | STTOPERVXITCOND |
|
| Response: | 0 |
|
Related Commands STATus:OPERation:VXITrigger?
STATus:OPERation:VXITrigger:ENABle
VX1410A & VX1420A IntelliFrame Mainframe Instruction Manual | 3±51 |