STATus Subsystem
STATus:QUEStionable:TEMPerature:MAXimum?
Queries the maximum measurable temperatures in the mainframe since the last factory maintenance was performed; the returned value is in °C.
There is no command associated with this query.
Syntax | STATus:UEStiable:TEMPerature:MAXimum? <Lcati> | |||
Parameters |
|
|
|
|
| <Location> |
| Query response | |
|
| {AMBient OUT0 . . . OUT12 DELTa0 . . . DELTa12} | <NR1> | |
|
| AMBient ± ambient input temperature |
| |
|
| OUT0 . . . OUT12 ± output temperature of each slot |
| |
|
| DELTa0 . . . DELTa12 ± output temperature minus |
| |
|
| input temperature of each slot |
| |
Reset Value |
|
|
|
|
0 |
|
| ||
Errors and Events |
| ±224, ªIllegal Parameter Valueº | ||
|
| You attempted to use an illegal parameter value. | ||
Dependencies |
| None |
|
|
Examples |
| Query: | STAT:UES:TEMP:MAX? AMB | |
|
| Response: | 32 |
|
Related Commands | STATus:QUEStionable:TEMPerature:LEVel? | |||
| STATus:QUEStionable:TEMPerature:CMAXimum? |
3±90 | VX1410A & VX1420A IntelliFrame Mainframe Instruction Manual |