Replacing the Battery

Notice: Observe static precautions. Use an antistatic wrist strap.

1.Power off the system and remove the side panel as described earlier in this chapter.

2.Using your finger nail or a small pointed tool, gently push down the top edge of the battery and pry the battery out of its socket. Refer to Figure 5-9 for the socket location.

3.Orient the new battery over its socket so the plus (+) sign on the battery is facing up.

4.Carefully insert the bottom of the battery into the socket connectors and gently push the battery into the socket.

5.Press down on the battery until it is firmly seated in its socket.

6.Replace the side panel and turn on the system.

7.Run the SCU to restore configuration settings to the real-time-clock.