Status LED Indicator Descriptions
Table
Table 2-1. System Status LED Indicators
LED | Status | Description | Response |
|
|
|
|
Power Status | Off | Power OFF | None required (normal) |
|
|
|
|
| Green | Power ON | None required (normal) |
|
|
|
|
| Amber | System power supply failure | Replace failed power |
|
|
| supply module. |
|
|
|
|
System Status | Off | Power OFF | None required (normal) |
|
|
|
|
| Green | No alarms | None required (normal) |
|
|
|
|
| Amber | Abnormal condition | Replace failing part. |
|
| (see Table |
|
|
|
|
|
Disk Status | Off | Not accessing disk drives | None required (normal) |
|
|
|
|
| Amber | Internal disk drive failure | Replace disk drive |
|
|
|
|
| Green | Accessing disk drives | None required (normal) |
|
|
|
|
Table 2-2. Disk Drive Status LED Panel Indicators
LED | Status | Description | Response |
|
|
|
|
Disk Drive | Off | Disk drive power is OFF | None required (normal) |
Power |
|
|
|
|
|
|
|
| Green | Disk drive power is ON | None required (normal) |
|
|
|
|
Disk Drive | Off | Not accessing disk drives | None required (normal) |
Activity |
|
|
|
|
|
|
|
| On | Accessing disk drives | None required (normal |
|
|
|
|
Disk Drive | Off | No alarms | None required (normal) |
Status |
|
|
|
|
|
|
|
| Amber | Internal disk drive failure | Replace disk drive. |
|
|
|
|