7.Pull the faulty drive out of the bay far enough to disengage the drive connector from the backplane. Wait 30 seconds until the drive spins down, then remove the drive from the drive bay.

Notice: Observe static precautions. Use an antistatic wrist strap.

8.Remove the new drive from its protective wrapper, and place on an antistatic surface.

9.Record the drive model and serial numbers in the equipment log.

10.Position the drive so its SCA connector is near the top surface of the drive. Place drive on the antistatic surface again.

11.Slide the drive into the carrier with its SCA connector facing toward the front of the carrier (open end) if swapping drives (reuse the carrier from the faulty drive).

12.While holding the drive in the carrier with your left hand, align the drive’s screw holes with the carrier’s screw holes and insert the four screws of appropriate size and length (see Figure 5-15).

Figure 5-15. Installing Hard Disk in Carrier

 

 

Installing 3 1/2inch hard disk

 

 

drive in carrier for hot-swap

 

 