Installing or Swapping a Disk Drive in a Hot-swap Bay
This procedure describes installing a new drive in or swapping out a faulty drive from one of the six hot- swap drive bays. The 3
Note: To order a carrier contact your sales representative or dealer.
■If installing new drives, follow an installation scheme starting with the bottom left drive. Fill the bays left to right, across a row, and then move up a row.
■If an individual SCSI drive fault LED (yellow light) is on steadily, this indicates that the drive below it has been flagged as faulty by the SCSI host controller. Follow the procedure described in this section to remove the faulty drive and swap in a good one.
Note: Install or swap SCSI drives without turning
off power. This is one of the few system procedures that is safe to do with the system power left on. This is true only if a Redundant Array of Independent Disks (RAID) controller module is installed and only for the drive/carrier assemblies in the
Notice: ESD can damage disk drives, boards, and other parts. This system can withstand normal levels of environmental ESD while you are