4-31

Moving System Board Jumpers

Caution: Before doing the procedures in this section, make sure that your system is powered off and unplug the AC power cord from the back of the chassis. Failure to disconnect power before moving the jumpers can result in personal injury and equipment damage.

Notice: Observe static precautions. Use an antistatic wrist strap.

To configure the system board options:

1.Power off the system and remove the covers as described in Chapter 5 of this guide.

2.Check to ensure the system power cord is removed from the back of the system.

3.Locate the position of the jumpers on the system board you are changing. Refer to Figure 4-2.

4.To change a jumper setting, use a pair of needle- nose pliers or your fingers to remove the jumper from its current location. Position the jumper over the two pins for the desired setting and press it onto the pins. Be careful not to bend the pins. Refer to Table 3-8 for system board jumper settings.

5.Record changes to the system board jumpers in Table 4-8.

6.Install the system covers and power up the system using procedures in chapter 5 of this guide.

7.Run the SCU utility to verify your reconfiguration of the system board.

Configuring Your System

Page 84
Image 84
Zenith Data Systems MT2000 manual Moving System Board Jumpers