3Com 3CRDSF9PWR manual To test cables, Diagnostics

Models: 3CRDSF9PWR

1 256
Download 256 pages 60.62 Kb
Page 222
Image 222

222CHAPTER 18: MANAGING DEVICE DIAGNOSTICS

To test cables:

1Click Monitoring > Cable Diagnostics > Diagnostics. The Diagnostics Page opens:

Figure 114 Diagnostics Page

The Diagnostics Page contains the following fields:

Select a Port — Selects the port to be tested.

Test Result — Displays the cable test results. Possible values are:

OK — Indicates that the cable passed the test.

Failed — Indicates that the cable failed the test. The test will fail if a cable is not connected to the port, the cable is connected on only one side, the cable is shorter than one meter, or a short has occurred in the cable.

Cable Fault Distance — Indicates the distance in meters from the port where the cable error occurred.

A Cable Fault Distance of 0M can result from a short (< 1 meter) cable, an open cable or a 2-pair copper cable.

Last Update — Indicates the last time the port was tested.

2Select a port to be tested. The port is tested, and the page is updated.

Page 222
Image 222
3Com 3CRDSF9PWR manual To test cables, Diagnostics