Refer to AAA Operation and SSH Operation of this manual for information about AAA, RADIUS, and SSH.

Configuration Example

Network requirements

As shown in Figure 3-3, assume a current user logs in using the oap connect slot 0 command and the user level is set to the manage level (level 3). Perform the following configurations for users logging in to VTY 0 using Telnet.

z

z

z

z

z

z

z

z

Configure the local user name as guest.

Set the authentication password of the local user to 123456 (in plain text). Set the service type of VTY users to Telnet and the command level to 2. Configure to authenticate users logging in to VTY 0 in scheme mode. Only Telnet protocol is supported in VTY 0.

The screen can contain up to 30 lines.

The history command buffer can store up to 20 commands. The timeout time of VTY 0 is 6 minutes.

Figure 3-3Network diagram for Telnet configuration (with the authentication mode being scheme)

 

RS-232 serial

Console port

 

 

interface

 

 

Console cable

PC

Switching engine

Configuration procedure

# Enter system view.

<device> system-view

# Create a local user named guest and enter local user view.

[device] local-user guest

# Set the authentication password of the local user to 123456 (in plain text).

[device-luser-guest] password simple 123456

# Set the service type to Telnet, Specify commands of level 2 are available to users logging in to VTY 0.

[device-luser-guest] service-type telnet level 2

[device-luser-guest] quit

# Enter VTY 0 user interface view.

[device] user-interface vty 0

# Configure to authenticate users logging in to VTY 0 in the scheme mode.

[device-ui-vty0] authentication-mode scheme

# Configure Telnet protocol is supported.

3-10