3Com WX3000 operation manual Destination-port, Test-type jitter

Models: WX3000

1 715
Download 715 pages 21.26 Kb
Page 621
Image 621

5)Configuring jitter test on HWPing client

Follow these steps to configure jitter test on HWPing client:

To do…

Use the command…

Remarks

Enter system view

system-view

 

 

 

Enable the HWPing client

 

Required

hwping-agent enable

By default, the HWPing client

function

 

function is disabled.

 

 

 

 

 

Create a HWPing test group

hwping administrator-name

Required

By default, no test group is

and enter its view

operation-tag

configured.

 

 

 

 

 

 

 

Required

 

 

The destination address must

Configure the destination IP

 

be the IP address of a UDP

destination-ip ip-address

listening service on the

address

 

HWPing server.

 

 

 

 

By default, no destination

 

 

address is configured.

 

 

 

 

 

Required

 

destination-port

The destination port must be

Configure the destination port

the port of a UDP listening

Port-number

service on the HWPing server.

 

 

 

By default, no destination port

 

 

is configured.

 

 

 

Configure the source IP

 

Optional

source-ip ip-address

By default, no source IP

address

 

address is configured.

 

 

 

 

 

 

 

Optional

Configure the source port

source-port port-number

By default, no source port is

 

 

configured.

 

 

 

 

 

Required

Configure the test type

test-type jitter

By default, the test type is

 

 

ICMP.

 

 

 

Configure the number of

 

Optional

count times

By default, each test makes

probes per test

 

one probe.

 

 

 

 

 

Configure the maximum

 

Optional

number of history records that

history-records number

By default, the maximum

can be saved

 

number is 50.

 

 

 

 

 

Optional

Configure the packet size

datasize size

By default, the packet size is 68

 

 

bytes.

 

 

 

 

 

Optional

Configure the automatic test

frequency interval

By default, the automatic test

interval is zero seconds,

interval

 

indicating no automatic test will

 

 

 

 

be made.

 

 

 

1-10

Page 621
Image 621
3Com WX3000 operation manual Destination-port, Test-type jitter