[Switch] info-center enable

# Disable the function of outputting information to the console channels.

[Switch] undo info-center source default channel console

#Enable log information output to the console. Permit ARP and IP modules to output log information with severity level higher than informational to the console.

[Switch] info-center console channel console

[Switch] info-center source arp channel console log level informational debug state off trap

state off

[Switch] info-center source ip channel console log level informational debug state off trap

state off

# Enable terminal display.

<Switch> terminal monitor

<Switch> terminal logging

Configuration Example

Network requirements

z

z

z

As shown in Figure 1-4, the device is in the time zone of GMT+ 08:00:00. The time stamp format of output log information is date.

UTC time zone will be added to the output information of the information center.

Figure 1-4Network diagram

Internet

Switch

PC

Configuration procedure

# Name the local time zone z8 and configure it to be eight hours ahead of UTC time.

<Switch> clock timezone z8 add 08:00:00

# Set the time stamp format of the log information to be output to the log host to date.

<Switch> system-view

System View: return to User View with Ctrl+Z. [Switch] info-center timestamp loghost date

# Configure to add UTC time to the output information of the information center.

[Switch] info-center timestamp utc