z

z

z

z

A Smart Link/Monitor Link group with members cannot be deleted. A Smart Link group as a Monitor Link group member cannot be deleted.

The Smart Link/Monitor Link function and the remote port mirroring function are incompatible with each other.

If a single port is specified as a Smart Link/Monitor Link group member, do not use the lacp enable command on the port or add the port to another dynamic link aggregation group because doing so will cause the port to become an aggregation group member.

Using the copy command on a port does not copy the Smart Link/Monitor Link group member information configured on the port to any other port.

Displaying and Maintaining Monitor Link

 

To do…

 

Use the command…

 

Remarks

 

Display the information about

 

display monitor-link group

 

Available in any view

 

one or all Monitor Link groups

 

{ group-id all }

 

 

 

 

 

 

 

 

 

 

 

Monitor Link Configuration Example

Implementing Collaboration Between Smart Link and Monitor Link

Network requirements

As shown in Figure 2-3, the PCs access the server and Internet through the device. Configure Smart Link and Monitor Link to prevent the PCs from failing to access the server and Internet due to uplink link or port failure.

2-5