1-8
To do… Use the command… Remarks
Log host
direction info-center timestamp
loghost date
Set the time
stamp format
in the output
direction of
the
information
center to
date
Non log host
direction info-center timestamp { log |
trap | debugging } date
Required
Use either command
Set to display the UTC time zone
in the output information of the
information center info-center timestamp utc
Required
By default, no UTC time zone
is displayed in the output
information
Setting to Output System Information to the Console

Setting to output system information to the console

Follow these steps to set to output system information to the console:
To do… Use the command… Remarks
Enter system view system-view
Enable the information center info-center enable Optional
Enabled by default.
Enable system information
output to the console
info-center console channel
{ channel-number |
channel-name }
Optional
By default, the device uses
information channel 0 to output
log/debugging/trap information
to the console.
Configure the output rules of
system information
info-center source
{ modu-name | default }
channel { channel-number |
channel-name } [ { log | trap |
debug } { level severity | state
state } ]*
Optional
Refer to Table 1-4 for the
default output rules of system
information.
Set the format of time stamp in
the output information
info-center timestamp { log |
trap | debugging } { boot |
date | none }
Optional
By default, the time stamp
format of the log and trap
output information is date, and
that of the debugging output
information is boot.
To view the debugging information of some modules on the device, you need to set the type of the
output information to debug when configuring the system information output rules, and use the
debugging command to enable debugging for the corresponding modules.