2)Enable Monitor Link on Switch C and Switch D and enable the function of processing flush messages received from VLAN 1. Perform the following configuration on Switch C. The operation procedure on Switch D is the same as that performed on Switch C.

# Enter system view.

<SwitchC> system-view

# Create Monitor Link group 1 and enter Monitor Link group view

[SwitchC] monitor-link group 1

#Configure GigabitEthernet 1/0/1 as the uplink port of the Monitor Link group and GigabitEthernet 1/0/2 and GigabitEthernet 1/0/3 as the downlink ports.

[SwitchC-mtlk-group1] port GigabitEthernet 1/0/1 uplink

[SwitchC-mtlk-group1] port GigabitEthernet 1/0/2 downlink

[SwitchC-mtlk-group1] port GigabitEthernet 1/0/3 downlink

#Return to system view. Enable the function of processing flush messages received from VLAN 1 on GigabitEthernet 1/0/2 and GigabitEthernet 1/0/3.

[SwitchC-mtlk-group1] quit

[SwitchC] smart-link flush enable control-vlan 1 port GigabitEthernet 1/0/2 to

GigabitEthernet 1/0/3

3)Enable the function of processing flush messages received from VLAN 1 on GigabitEthernet 1/0/10 and GigabitEthernet 1/0/11 of Switch E.

# Enter system view.

<SwitchE> system-view

#Enable the function of processing flush messages received from VLAN 1 on GigabitEthernet 1/0/10 and GigabitEthernet 1/0/11.

[SwitchE] smart-link flush enable control-vlan 1 port GigabitEthernet 1/0/10 to

GigabitEthernet 1/0/11

2-7

Page 666
Image 666
3Com WX3000 operation manual SwitchC monitor-link group