To do…

 

Use the command…

 

Remarks

 

 

Configure the number of

 

 

Optional

 

 

 

count times

By default, each test makes one

 

 

probes per test

 

 

 

 

 

probe.

 

 

 

 

 

 

 

 

 

 

 

 

 

Configure the maximum

 

 

Optional

 

 

number of history records that

 

history-records number

By default, the maximum number

 

 

can be saved

 

 

is 50.

 

 

 

 

 

 

 

 

 

 

 

 

 

Optional

 

 

Configure the automatic test

 

frequency interval

 

By default, the automatic test

 

 

 

 

interval is zero seconds,

 

 

interval

 

 

 

 

 

 

 

indicating no automatic test will be

 

 

 

 

 

 

 

 

 

 

 

 

made.

 

 

 

 

 

 

 

 

Configure the probe timeout

 

 

Optional

 

 

 

timeout time

By default, a probe times out in

 

 

time

 

 

 

 

 

three seconds.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Optional

 

 

Configure the type of service

 

tos value

 

By default, the service type is

 

 

 

 

 

 

zero.

 

 

 

 

 

 

 

 

 

 

 

Optional

 

 

Configure the type of FTP

 

ftp-operation { get put }

By default, the type of FTP

 

 

 

operation is get, that is, the FTP

 

 

operation

 

 

 

 

 

 

operation will get a file from the

 

 

 

 

 

FTP server.

 

 

 

 

 

 

 

 

 

Configure an FTP login

 

username name

 

Required

 

 

username

 

 

 

 

 

 

 

By default, neither username nor

 

 

 

 

 

 

 

 

Configure an FTP login

 

 

 

 

 

 

password password

 

password is configured.

 

 

password

 

 

 

 

 

 

Configure a file name for the

 

 

Required

 

 

 

filename file-name

By default, no file name is

 

 

FTP operation

 

 

 

 

 

configured for the FTP operation

 

 

 

 

 

 

 

 

 

 

 

 

 

Start the test

 

test-enable

Required

 

 

 

 

 

 

 

 

 

 

 

display hwping results

 

Required

 

 

Display test results

 

 

You can execute the command in

 

 

 

[ admin-name operation-tag ]

 

 

 

 

 

 

any view.

 

 

 

 

 

 

 

 

 

 

 

 

 

4)Configuring HTTP test on HWPing client

Follow these steps to configure HTTP test on HWPing client:

 

To do…

 

Use the command…

 

Remarks

 

Enter system view

 

system-view

 

 

 

 

 

 

 

 

Enable the HWPing client

 

 

 

Required

 

 

hwping-agent enable

 

By default, the HWPing client

 

function

 

 

 

 

 

 

function is disabled.

 

 

 

 

 

 

 

 

 

 

 

Create a HWPing test group

 

hwping administrator-name

Required

 

 

By default, no test group is

 

and enter its view

operation-tag

 

configured.

 

 

 

 

 

 

 

 

 

 

1-8