z

z

z

z

z

z

When you copy a port, the Smart Link/Monitor Link group member information configured on the port will not be copied to other ports.

If a single port is specified as a member of a Smart Link/Monitor Link group, you cannot execute the lacp enable command on this port or add this port into other dynamic link aggregation groups, because these operations will make this port become a link aggregation group member.

If no control VLAN is configured for flush message processing, the device will forward received flush messages without processing them.

If the control VLAN for receiving flush messages configured on an associated device is different than the one for sending flush messages configured on the corresponding Smart Link device, the device will forward received flush messages without processing them.

In the static or manual link aggregation group which serves as a Smart Link group member, if a member port can process flush messages, this function cannot be synchronized to the other ports in the aggregation group automatically, that is, the other member ports in the aggregation group cannot process flush messages. The function of processing flush messages must be manually configured for each port in the aggregation group.

The VLAN configured as a control VLAN to send and receive flush messages must exist. You cannot directly remove the control VLAN. When a dynamic VLAN is configured as the control VLAN for the Smart Link group, this VLAN will become a static VLAN, and the prompt information is displayed.

Displaying and Maintaining Smart Link

 

To do…

Use the command…

Remarks

 

Display the information of a

display smart-link group { group-id

 

 

Smart Link group

all }

 

 

 

 

 

 

Display the statistics

 

Available in any view

 

information of flush messages

display smart-link flush

 

 

received and processed by the

 

 

 

 

 

current device

 

 

 

 

 

 

 

Clear flush message statistics

reset smart-link packets counter

Available in any view

 

 

 

 

Smart Link Configuration Example

Implementing Link Redundancy Backup

Network requirements

As shown in Figure 1-3, Switch A is a WX3000 series device. Switch C, Switch D and Switch E support Smart Link. Configure Smart Link feature to provide remote PCs with reliable access to the server.

1-6

Page 657
Image 657
3Com WX3000 Displaying and Maintaining Smart Link, Smart Link Configuration Example, Implementing Link Redundancy Backup