224 | Appendix E: Codes and error messages | ||
|
|
|
|
Code | Error Message | Failure Description | |
|
|
|
|
0B60: | DIMM bank 1 has been | Memory error, memory bank | |
| disabled | 1 failed | |
|
|
|
|
0B61: | DIMM bank 2 has been | Memory error, memory bank | |
| disabled | 2 failed | |
|
|
|
|
0B62: | DIMM bank 3 has been | Memory error, memory bank | |
| disabled | 3 failed | |
|
|
|
|
0B6F: | DIMM bank with error is | An error detected in all the | |
| enabled | memory | |
|
|
|
|
0B70: | The error occurred during | Error while detecting a | |
| temperature sensor reading | temperature failure. | |
|
|
|
|
0B71: | System temperature out of | Temperature error detected. | |
| the range |
|
|
|
|
|
|
0B74: | The error occurred during | Error while detecting voltage | |
| voltage sensor reading |
|
|
|
|
|
|
0B75: | System voltage out of the | System voltage error | |
| range |
|
|
|
|
|
|
0B7C: | The error occurred during | The error occurred while | |
| redundant power module | retrieving the power | |
| confirmation | information. | |
|
|
|
|
0B80: | BMC Memory Test Failed | BMC device (chip) failed | |
|
|
|
|
0B81: | BMC Firmware Code Area | BMC device (chip) failed | |
| CRC check failed |
|
|
|
|
|
|
0B82: | BMC core Hardware failure | BMC device (chip) failed | |
|
|
|
|
0B83: | BMC IBF or OBF check failed | Access to BMC address failed | |
|
|
|
|
0B90: | BMC Platform Information | BMC device (chip) failed | |
| Area corrupted. |
|
|
|
|
|
|
0B91: | BMC update firmware | BMC device (chip) failed | |
| corrupted. |
|
|
|
|
|
|