vi

Multiple power cords

Warning! To avoid electrical shock, disconnect all AC power cords before accessing inside the system.

Earth grounded socket-outlets

Warning! To avoid electrical shock, the system power cord(s) must be plugged into socket-outlet(s) that is provided with a suitable earth ground.

Precautionary reminders

Over current protection

The system is designed to operate on a 20A AC voltage source that is provided with 20A over current protection. If the AC source for the rack exceeds 20A over current protection, each system must be provided with 20A or less over current supplemental protection. The supplementary over current protection must have the appropriate regional safety certifications for the over current application.

Power supply modules

Power supply modules have double-pole/neutral fusing.

Ventilation considerations

The equipment rack must provide sufficient airflow to the front of the system to maintain proper cooling. The rack selected and the ventilation provided must be suitable to the environment in which the system will be used.

Fans

To avoid injury do not touch moving fan blades.

Cooling and airflow

For proper cooling and airflow, always install all access covers before turning on the system. Operating the system for longer than five minutes without the covers in place can cause overheating and damage to system components.

Temperature limits

The operating temperature of the system, when installed in the rack, must not go below 10°C (50°F) or rise above 35°C (95°F). Extreme fluctuations in temperature may cause a variety of problems in system, and safety limits may be broken.

Lifting and Moving

Do not attempt to lift or move the server by the handles on the power supplies.

Page 6