164

Appendix B: System management

Platform event management

Events can trigger alerts and other actions by the BMC. The server is configured with the following set of standard events:

Temperature sensor out of range

Voltage sensor out of range

Fan failure

Chassis intrusion

Power supply fault

BIOS uncorrectable ECC error

BIOS POST error

Processor fault resilient booting (FRB) failure

Fatal nonmaskable interrupt (NMI) from a source other than the front panel switch

Watchdog timer reset, power down, or power cycle

System restart (reboot)

Alerts can take either of these forms:

Platform event pages

The BMC dials a paging service and sends a predefined paging string. To use platform event paging (PEP), you must attach an external modem to the emergency management port (COM2).

BMC LAN alerts

The BMC sends an alert to a predefined destination on the LAN.

You can configure PEP and BMC LAN alerts by using the System Setup Utility (refer to page 166).

Page 180
Image 180
Acer G901 manual Platform event management