181
• Subnet Mask | The IP address for the server's subnet. The |
| server uses this to decide if the alert |
| destination is on the same subnet. |
7Click Save to save the changes.
8Click Close to return to the PEM window.
Setting up remote modem or serial access
To configure remote modem or serial access:
1From the SSU Main window, choose Platform Event Manager (PEM).
2In the PEM window, click Configure EMP.
3If you want to require a password for remote access, enter the password in the Enter New Password box and in the Verify New Password box.
Passwords can be from 1 to 16 characters long, using any ASCII character in the range
4In the Modem Ring Time box, enter the number of 500ms intervals that the BMC should wait before taking control of the COM2 port and answering an incoming call.
A value greater than zero gives the BIOS time to answer before the BMC takes control. A value of zero causes the BMC to answer immediately. The maximum value, 63, tells the BMC to ignore the call. Modem Ring Time applies only to Preboot access mode and is ignored for other access modes.
5In the System Phone Number box, enter the number for the phone line connected to the modem on the EMP.
6From the Access Mode list, choose the remote access mode:
• | Always Active | The EMP is available at any time. |
• | Preboot | The EMP is available only when the server is |
|
| powered down or is in the running POST |
|
| during startup. |