MERLIN LEGEND
Voice Port Requirements
The Intuity system voice ports must be connected to tip/ring ports on a Basic Telephone Module
There are two limitations on the number of Intuity voice ports that can be connected to the same BTM:
■Ring Blocking
A maximum of four ports on a BTM can be rung at any one time. Due to this limitation, a maximum of eight ports on a BTM can be used for Intuity voice ports.
■
Two TTRs are provided on each BTM. Unless additional TTRs are available, a maximum of four ports on a BTM can be used for Intuity voice ports. Additional TTRs are provided on 400 GS/LS/TTR, 400 LS/TTR and other circuit modules. Approximately one TTR is required for each two Intuity voice ports, but the level of system activity may make TTRs on other circuit modules unavailable for Intuity voice port use. Consult the MERLIN LEGEND Communication System documentation for more details.
As a general rule, use a separate BTM board for every four ports unless additional
Unused BTM ports may be used for
Table
Intuity Voice Ports | Ringing SLS, Modems, FAX |
8 | 0 |
7 | 0 |
6 | 1 |
5 | 2 |
4 | 2 |
3 | 3 |
2 | 3 |
1 | 4 |