Intuity System Connections
Use the information and diagrams in this section to connect or verify the connections for the Intuity system with a MERLIN LEGEND switch.
IVC6 Connections
There are two methods commonly used to connect IVC6 boards:
■Using an 885A adapter to connect to RJ11C connections
■Connecting to a type 104B connecting block
Connect IVC6 Boards Using 885A Adapter:
Connect IVC6 boards using an 885A adapter as follows:
1.Make sure that the line pairs were run individually (RJ11C).
2.Use a type 885A adapter to consolidate the six individual line pairs into three pairs in each of two cables. (See Figure
3.There is an adhesive strip on the back of the 885A adapter. Remove the protective coating paper, and attach the 885A adapter in a convenient place.
4.Use the supplied
5.Use the supplied 2- or 4- conductor modular cables between the adapter and the RJ11C modular jacks.
6.Label the connections in the space provided on the 885A adapter.
NOTE:
The label on the 885A adapter refers to an IVP6. This should be interpreted as an IVC6.