Intuity System Connections

Use the information and diagrams in this section to connect or verify the connections for the Intuity system with a MERLIN LEGEND switch.

IVC6 Connections

There are two methods commonly used to connect IVC6 boards:

Using an 885A adapter to connect to RJ11C connections

Connecting to a type 104B connecting block

Connect IVC6 Boards Using 885A Adapter:

Connect IVC6 boards using an 885A adapter as follows:

1.Make sure that the line pairs were run individually (RJ11C).

2.Use a type 885A adapter to consolidate the six individual line pairs into three pairs in each of two cables. (See Figure 4-1.)

3.There is an adhesive strip on the back of the 885A adapter. Remove the protective coating paper, and attach the 885A adapter in a convenient place.

4.Use the supplied 6-conductor modular cables between the IVC6 board and the adapter.

5.Use the supplied 2- or 4- conductor modular cables between the adapter and the RJ11C modular jacks.

6.Label the connections in the space provided on the 885A adapter.

NOTE:

The label on the 885A adapter refers to an IVP6. This should be interpreted as an IVC6.