MERLIN LEGEND Switch

5

Administration

 

This chapter describes how to administer the MERLIN LEGEND system for integration with the Intuity system. Be sure to have the MERLIN LEGEND system forms that you completed in Chapter 2.

Disconnect Signaling Reliability

Use this procedure to classify the disconnect signal sent by the central office on loop-start trunks as reliable. The selected setting applies to all trunks in the system; trunks cannot be programmed individually. The disconnect signaling reliability does not apply to ground-start trunks emulated on a T1 facility.

To set the disconnect signaling reliability:

1.From the System Programming menu, select Lines and Trunks.

On the console: Select LinesTrunks.

On the PC: Press F4 .

The Lines and Trunks menu appears.

2.Select Touch-Tone/Loop Start Disconnect.

On the console: Select TT/LS Disc.

On the PC: Press F3 .

The TouchTone/LS Disconnect menu appears.

3.Select Loop Start Disconnect.

On the console: Select LS Disconnect.

On the PC: Press F2 .

The LS Reliable Disconnect menu appears.

Issue 2.0 December 1995 5-1

Page 92
Image 92
AT&T 585-310-231 manual Merlin Legend Switch Administration, Disconnect Signaling Reliability