Refer to Figure 4-10.Connect the Intuity low speed networking by following these steps:

1.Connect one end of the ACCX cable to the connector on the ACCX card.

2.Connect the other end of the ACCX cable to the matching connector on the break-out box.

3.Connect one end of the DB-25 M-M cable to the connector marked RS-232-CH1 (2, 3, or 4) on the break-out box.

4.Connect the other end of the DB-25 M-M cable to the matching connector on the modem.

5.Connect one end of the modular cord to the jack marked DIAL on the modem.

6.Depending on whether or not the MERLIN LEGEND system is equipped with DID lines:

If the system does not have DID lines, connect the other end of the modular cord to a RJ11C telephone jack wired to a Loop Start (LS) line from the CO.

If the system has DID lines, con nect the other end of the modular cord to a MERLIN LEGEND Tip/Ring port that has an assigned DID number.

NOTE:

If building wire is used, it must be type 3 UTP or better. The distance limitation is the same as for a station.

7.Connect the power supply connector to the modem.

8.Plug in the power supply.

9.Turn on power for the modem.

Issue 2.0 December 1995 4-19