Two D8W-87 Modular Cords

M7-U87 Crossover Cable

Two Z3A2 ADUs

Two M8AJ-87 Cable

D8AM-87 Modular Crossover Cable

Two 400B2 Adapters

Two D6AP-87 Modular Cords

Two 248B Adapters

Two 2012D Power Transformers

NOTE:

The combination of a Z3A2 ADU and a M8AJ-87 cable is equivalent to a Z3A4 ADU. You must order both pieces (one of each for Admin port, another of each for SMDR port).

NOTE:

Inside wire must be 4-pair, suitable for data; type 3 UTP data cable or better.

NOTE:

Local powering of the Z3A2 ADU is optional.

Connect to the first available port on the Multi-Port Serial Card.

Refer to Figure 4-13Connect the terminal and the Intuity system by following these steps:

1.Connect one end of the M7U-87 crossover cable to the terminal.

2.Connect the other end of the M7U-87 cable to the matching end of a M8AJ-87 cable.

3.Connect the other end of the M8AJ-87 cable to the matching connector on a Z3A2 ADU.

4.Connect one end of a D8W-87 modular cord to the modular jack marked WALL on the Z3A2 ADU.

5.Connect the other end of the D8W-87 modular cord to the modular jack end of a D8AM-87 crossover cord.

6.Connect the modular plug end of the D8AM-87 crossover cord to the matching modular jack on a 400B2 adapter.

7.Plug the 400B2 adapter into the wall jack leading to the Intuity system site.

8.Connect one end of a D6AP-87 modular cord to the 400B2 adapter.