■The preferred order of connection of the devices is:
—MERLIN LEGEND administration
—optional Remote Maintenance M odem
—optional Call A ccounting System (SMDR)
—optional customer remote access terminals or modems
If the MERLIN LEGEND system is within 50 feet (15 meters) of the Intuity system, and the MERLIN LEGEND system and the Intuity system share the same power outlet, a direct connection can be made between the MERLIN LEGEND administration and optional SMDR ports and the Intuity system ports.
If the MERLIN LEGEND system is farther than 50 feet (15 meters) from the Intuity system, or the MERLIN LEGEND system and the Intuity system do not share the same power outlet, data cables from the MERLIN LEGEND system administration and optional SMDR ports to the Intuity system ports have to be extended with Z3A2 ADU cable drivers. Two Z3A2 ADU interface units are required for each cable, one at each end.
The optional Remote Maintenance Modem must be
Optional customer access terminals may be
Connecting Administration Ports
Within 50 feet, Same Power Outlet
This method is used only when the MERLIN LEGEND Communications System and the Intuity system are within 50 feet and share the same power outlet.
The following parts are required:
■
■355AF Adapter
■
Refer to Figure
1.Connect one end of a
2.Connect the other end of the