Configure Polycom MGC Video Conferencing Bridge Platforms with Avaya S8500 and S87xx Server
Issue 3 January 2008 85
Outgoing Rules
Keep in mind the following information:
Change dial plan analysis and uniform dial plan as required to support the Polycom
MGC-assigned extension range.
Add AAR analysis for dial plan extension range for use by the Polycom MGC system. Use
lev0 as the type to force use of the private numbering plan.
On the route pattern form, add an entry for each outgoing trunk group, and set LAR to
next. Only one route pattern should be required per Polycom MGC system.
Regarding digit manipulation, present the digits to the Polycom MGC system in the form of
“prefix” plus digits. For example, suppose the Polycom MGC system is administered with
the prefix 7, and there is a five-digit dial plan with 715xx routing to the Polycom MGC
system. You should present the digits 715xx instead of 15xx, where 15xx is the meeting
rooms. The Polycom MGC system allows support of multiple prefixes.