Configure a Polycom RMX Series Video Conferencing Bridge Platform
4.Set Carrier Medium to H.323.
5.Set Service Type to tie.
Procedure 3: Add a Signaling Group for the RMX System
To add a signaling group for the RMX system:
1.Use the add
The Signaling Group form appears.
Figure 13: Example of Page 1 of the Signaling Group Form
2.Set Group Type to h.323.
3.Set IP Video to y.
4.Set Priority Video. If you want all incoming calls to receive priority video transmissions, select y.
5.Set Trunk Group for Channel Selection to the
6.Set
Issue 3 January 2008 67