SIP Station Administration (OPTIM)

SIP Station Administration (OPTIM)

Question 1: Is the IP station configured to use video?

Verify that the fields have been configured correctly on page 1 of the station form. "IP Video?" must be set to "y."

†Yes.

†No. Expect no video media if video is disabled for the station.

Question 2: Is the IP station configured to use direct media?

Verify that the fields have been configured correctly on page 2 of the station form. "Direct IP-IP Audio Connections?" must be set to "y."

†Yes.

†No. Expect no video media if direct media is disabled for a station.

Question 3: Is the station type correct for the SIP endpoint being administered?

Verify that the fields have been configured correctly on page 1 of the station form. "Type" must be set to "4620SIP" or "96xx."

For Avaya endpoints, ensure that the set type matches. All OPTIM video endpoints should use the "4620SIP" station type.

†Yes.

†No. An incorrect set type can cause registration failure or call setup failure.

Question 4: Is the OPTIM call limit configured to allow the number of simultaneous call appearances required by the endpoint?

Verify that the fields have been configured correctly on page 2 of the off-pbx-telephone station-mapping form. "Call Limit" should be set to the number of extensions/line appearances.

†Yes.

†No. Certain station features may be unavailable, or multipoint capabilities may not work as expected.

Issue 3 January 2008 45

Page 45
Image 45
Avaya 16-601423 manual SIP Station Administration Optim, Question 1 Is the IP station configured to use video?