Section 5 - Troubleshooting

 

 

Electrical System

 

 

 

Electrical System

 

 

 

 

 

Problem

Possible Cause

Correction

 

 

 

 

 

 

Tractor runs for a short

Automatic shutdown mode activated.

Check audio and visual indicators for

time and shuts off

 

cause of shutdown. Contact Buhler

 

 

Versatile dealer.

 

Partially restricted fuel line.

Contact Buhler Versatile dealer.

 

 

 

 

 

 

Electrical system high/

Loose or corroded terminal

Clean and tighten connections.

low voltage

connections.

 

 

Shorted out electrical system.

Contact Buhler Versatile dealer.

 

Sulfated batteries.

Check each battery open circuit

 

 

voltage for 12.6 volts minimum.

 

 

Check electrolyte level and specific

 

 

gravity.

 

Loose or worn belt.

Check alternator belt tension.

 

 

Replace belt if required.

 

 

 

 

 

 

Batteries will not charge

Loose or corroded terminal

Clean and tighten connections.

 

connections.

 

 

One or more batteries defective or

Check each battery open circuit

 

sulfated.

voltage for 12.6 volts minimum.

 

 

Check electrolyte level and specific

 

 

gravity.

 

Loose or worn belt.

Check alternator belt tension.

 

 

Replace belt if required.

 

 

 

435/485/535