5-11 Section 5 - Troubleshooting
Hydraulic System
Hydraulic System - Electro-Hydraulic
Faults occurring in the EHR system (optional) will be indicated by a code flashed in the left hand, timed detent switch (1) in each of the EHR control pods. Faults for both sections in the pod will be indicated.
Pod | Section | Pod | Section |
|
|
|
|
1 | 1A+1B, 2A+2B | 3 | 5A+5B, 6A+6B |
|
|
|
|
2 | 3A+3B, 4A+4B | 4 | 7A+7B, 8A+8B |
|
|
|
|
ON |
N |
N |
1 |
No. of | Description of Error | Corrective Action | |
Flashes | |||
|
| ||
|
|
| |
1 | - | - | |
|
|
| |
2 | EERPOM inconsistent | Contact Buhler Versatile Dealer | |
|
|
| |
3 | Solenoid 1A open | Check wiring harness connection to Solenoid on implement valve 1A / | |
|
| Contact Buhler Versatile Dealer | |
|
|
| |
4 | Solenoid 1B open | Check wiring harness connection to Solenoid on implement valve 1B / | |
|
| Contact Buhler Versatile Dealer | |
|
|
| |
5 | Solenoid 2A open | Check wiring harness connection to Solenoid on implement valve 2A / | |
|
| Contact Buhler Versatile Dealer | |
|
|
| |
6 | Solenoid 2B open | Check wiring harness connection to Solenoid on implement valve 2B / | |
|
| Contact Buhler Versatile Dealer | |
|
|
| |
7 | Lever 1 pot open or short to ground | Check wiring harness connection to Lever 1 and 2 | |
|
| Contact Buhler Versatile Dealer | |
|
|
| |
8 | Lever 1 pot short to power | Check wiring harness connection to Lever 1 and 2 | |
|
| Contact Buhler Versatile Dealer | |
|
|
| |
9 | Lever 1 active switch open or short to | Check wiring harness connection to Lever 1 and 2 | |
| GRND | Contact Buhler Versatile Dealer | |
|
|
| |
10 | Lever 1 active switch short to power | Check wiring harness connection to Lever 1 and 2 | |
|
| Contact Buhler Versatile Dealer | |
|
|
| |
11 | Lever 1 full flow switch short to PWR | Check wiring harness connection to Lever 1 and 2 | |
|
| Contact Buhler Versatile Dealer | |
|
|
| |
12 | Lever 1 float switch open or short to | Check wiring harness connection to Lever 1 and 2 | |
| GRND | Contact Buhler Versatile Dealer | |
|
|
| |
13 | Lever 1 float switch short to power | Check wiring harness connection to Lever 1 and 2 | |
|
| Contact Buhler Versatile Dealer | |
|
|
| |
14 | Lever 2 pot open or short to ground | Check wiring harness connection to Lever 1 and 2 | |
|
| Contact Buhler Versatile Dealer | |
|
|
| |
15 | Lever 2 pot short to power | Check wiring harness connection to Lever 1 and 2 | |
|
| Contact Buhler Versatile Dealer | |
|
|
| |
16 | Lever 2 active switch open or short to | Check wiring harness connection to Lever 1 and 2 | |
| GRND | Contact Buhler Versatile Dealer | |
|
|
| |
17 | Lever 2 active switch short to power | Check wiring harness connection to Lever 1 and 2 | |
|
| Contact Buhler Versatile Dealer | |
|
|
| |
18 | Lever 2 full flow switch short to PWR | Check wiring harness connection to Lever 1 and 2 | |
|
| Contact Buhler Versatile Dealer | |
|
|
| |
19 | Lever 2 float switch open or short to | Check wiring harness connection to Lever 1 and 2 | |
| GRND | Contact Buhler Versatile Dealer | |
|
|
| |
20 | Lever 2 float switch short to power | Check wiring harness connection to Lever 1 and 2 | |
|
| Contact Buhler Versatile Dealer | |
|
|
|