3-76

Section 3 - Operation

Hydraulic Operation - Manual

The second position (3) prevents the control lever from entering the float position..

H

N

R

N

3

F3-92

The final position (4) has two functions.. It will lock the

 

lever into the neutral position to prevent accidental

 

actuation of the lever.. If the lockout lever is moved to

 

this position while the control lever is in the retract

 

position, the control lever is limited to travel between

 

the float and retract positions.. This position can be

 

used for continuous flow applications..

 

By limiting the travel of the remote control lever from

 

returning to the neutral position during continuous

 

flow applications, the lockout will protect the hydraulic

 

system from pressure spikes created by hydraulically

 

driven implements during implement shutdown..

 

IMPORTANT: When shutting off hydraulically driven

4

implements, place the remote lever in the float position

 

to allow the implement to coast to a stop. Shut the

 

tractor off and place the remote lever in the

 

neutral position.

 

H

N

F3-93

435/485/535