| Section 5 - Troubleshooting | |
|
|
| Fault Codes | |
|
|
|
| |
|
|
|
| |
Fault | Warning | Cause | Action | |
Codes | Lamp | |||
|
| |||
F513 | B | Injector Metering Rail | Contact Buhler Versatile Inc (BVI) Service Center | |
|
| #2 Pressure Sensor Circuit - shorted low |
| |
|
|
|
| |
F514 | B | Injector Metering Rail | Contact Buhler Versatile Inc (BVI) Service Center | |
|
| #2 Pressure Malfunction |
| |
|
|
|
| |
F515 | B | Injector Metering Rail | Contact Buhler Versatile Inc (BVI) Service Center | |
|
| #2 Pressure High - Warning |
| |
F516 | B | Injector Metering Rail #2 Pressure Low | Contact Buhler Versatile Inc (BVI) Service Center | |
|
| - Warning |
| |
|
|
|
| |
F517 | B | Vehicle Speed Sensor Circuit | Contact Buhler Versatile Inc (BVI) Service Center | |
|
| - data incorrect |
| |
|
|
|
| |
F518 | B | Vehicle Speed Sensor Circuit | Contact Buhler Versatile Inc (BVI) Service Center | |
|
| - tampering has been detected |
| |
F519 | C | Accelerator Pedal Position Sensor Circuit | Contact Buhler Versatile Inc (BVI) Service Center | |
|
| - shorted high |
| |
|
|
|
| |
F520 | C | Accelerator Pedal Position Sensor Circuit | Contact Buhler Versatile Inc (BVI) Service Center | |
|
| - shorted low |
| |
|
|
|
| |
F521 | C | Accelerator Pedal Position Sensor Circuit | Contact Buhler Versatile Inc (BVI) Service Center | |
|
| - invalid frequency |
| |
|
|
|
| |
F522 | C | SAE J1939 Multiplexing Accelerator Pedal | Contact Buhler Versatile Inc (BVI) Service Center | |
|
| Sensor System Error |
| |
F523 | B | OEM Alternate torque validation switch | Contact Buhler Versatile Inc (BVI) Service Center | |
|
| - data incorrect |
| |
|
|
|
| |
F524 | B | Fuel Delivery Pressure Sensor Circuit | Contact Buhler Versatile Inc (BVI) Service Center | |
|
| - shorted high |
| |
|
|
|
| |
F525 | B | Fuel Delivery Pressure Sensor Circuit | Contact Buhler Versatile Inc (BVI) Service Center | |
|
| - shorted low |
| |
F526 | B | Fuel Pressure High - Warning | Contact Buhler Versatile Inc (BVI) Service Center | |
|
|
|
| |
F527 | B | Fuel Pressure Low - Warning | Contact Buhler Versatile Inc (BVI) Service Center | |
|
|
|
| |
F528 | B | Water in Fuel Sensor Circuit - shorted high | Contact Buhler Versatile Inc (BVI) Service Center | |
|
|
|
| |
F529 | B | Water in Fuel Sensor Circuit - shorted low | Contact Buhler Versatile Inc (BVI) Service Center | |
F530 | A | Water in Fuel Indicator High – Maintenance | Check for Water in Fuel Filter/ | |
|
|
| Contact Buhler Versatile Inc (BVI) Service Center | |
|
|
|
| |
F531 | B | Engine Oil Pressure Sensor Circuit - data | Contact Buhler Versatile Inc (BVI) Service Center | |
|
| incorrect |
| |
|
|
|
| |
F532 | B | Engine Oil Pressure Sensor Circuit - | Contact Buhler Versatile Inc (BVI) Service Center | |
|
| shorted high |
| |
F533 | B | Engine Oil Pressure Low - Warning | Check Engine Oil Level/ | |
|
|
| Contact Buhler Versatile Inc (BVI) Service Center | |
|
|
|
| |
F534 | A | Low Oil Level in the Centinel makeup oil | Contact Buhler Versatile Inc (BVI) Service Center | |
|
| tank |
| |
|
|
|
| |
F535 | B | Fuel Supply Pump Inlet Pressure Sensor | Contact Buhler Versatile Inc (BVI) Service Center | |
|
| Circuit - shorted high |
| |
F536 | B | Fuel Supply Pump Inlet Pressure Sensor | Contact Buhler Versatile Inc (BVI) Service Center | |
|
| Circuit – shorted low |
| |
|
|
|
|