4-39 Section 4 - Lubrication & Maintenance

Every 1000 Hours

Inspect the seal (1) on both new elements before installing.. Cracks or chips in the element sealing rubber indicate that the element is defective and must be replaced..

Install the elements into the canister.. Be sure that the seal on the end of the filters fully contacts the air cleaner body.. The wing nuts (2) have a small seal (3) on the inner face which should be in good condition before the wing nuts are tightened.. If the seals (3) are damaged, replace them.. Tighten the wing nuts securely..

Replacement outer (Primary) element P/N: 86034042

Replacement inner (Safety) element P/N: 86034041

NOTE: Replacement elements can be obtained from your Buhler Versatile dealer.

1

F4-53

2

3

F4-54

435/485/535

Page 172
Image 172
Buhler 535, 485, 435 manual Lubrication & Maintenance Every 1000 Hours