5-16

Section 5 - Troubleshooting

Fault Codes

Fault

Warning

Cause

Action

Codes

Lamp

 

 

F417

D

Engine air filter restriction

Check Air Filter/

 

 

 

Contact Buhler Versatile Inc (BVI) Service Center

 

 

 

 

F418

C & E

Engine Coolant Level Low - Critical

Check Engine Coolant Level/

 

 

 

Contact Buhler Versatile Inc (BVI) Service Center

 

 

 

 

F419

F

Alternator not charging

Contact Buhler Versatile Inc (BVI) Service Center

F440

B & G

Intake Manifold Temperature

Contact Buhler Versatile Inc (BVI) Service Center

 

 

Sensor #1 Circuit - shorted high

 

 

 

 

 

F441

B & G

Intake Manifold Temperature

Contact Buhler Versatile Inc (BVI) Service Center

 

 

Sensor #1 Circuit - shorted low

 

 

 

 

 

F442

C & G

Intake Manifold Temperature

Contact Buhler Versatile Inc (BVI) Service Center

 

 

#1 High - Critical

 

F443

B

Intake Manifold Pressure Sensor

Contact Buhler Versatile Inc (BVI) Service Center

 

 

#1 Circuit - shorted high

 

 

 

 

 

F444

B

Intake Manifold Pressure Sensor

Contact Buhler Versatile Inc (BVI) Service Center

 

 

#1 Circuit - shorted low

 

 

 

 

 

F445

B

Intake Manifold Pressure Sensor Circuit

Contact Buhler Versatile Inc (BVI) Service Center

 

 

- data incorrect

 

 

 

 

 

F454

C

Engine Speed High - Critical

Contact Buhler Versatile Inc (BVI) Service Center

F500

B

Accelerator Pedal Position Sensor Supply

Contact Buhler Versatile Inc (BVI) Service Center

 

 

Voltage Circuit - shorted high

 

 

 

 

 

F501

B

Accelerator Pedal and Speed/Position

Contact Buhler Versatile Inc (BVI) Service Center

 

 

Sensor #1 Supply Voltage Circuit

 

 

 

- shorted low

 

 

 

 

 

F502

B

Engine Speed/Position Sensor

Contact Buhler Versatile Inc (BVI) Service Center

 

 

#2 (Camshaft) Supply Voltage

 

F503

B

Hand Throttle Idle Validation Circuit

Contact Buhler Versatile Inc (BVI) Service Center

 

 

- data incorrect

 

 

 

 

 

F504

B

Hand Throttle Idle Validation Circuit

Contact Buhler Versatile Inc (BVI) Service Center

 

 

- shorted low

 

 

 

 

 

F505

C

Hand Throttle Idle Validation Circuit

Contact Buhler Versatile Inc (BVI) Service Center

 

 

- out of calibration

 

 

 

 

 

F506

B

Sensor Supply Voltage #1 Circuit

Contact Buhler Versatile Inc (BVI) Service Center

 

 

- shorted high

 

F507

B

Sensor Supply Voltage #1 Circuit

Contact Buhler Versatile Inc (BVI) Service Center

 

 

- shorted low

 

 

 

 

 

F508

B

Auxiliary Temperature Sensor Input

Contact Buhler Versatile Inc (BVI) Service Center

 

 

# 1 Circuit – shorted high

 

 

 

 

 

F509

B

Auxiliary Temperature Sensor Input

Contact Buhler Versatile Inc (BVI) Service Center

 

 

# 1 Circuit – shorted low

 

F510

B

Auxiliary Pressure Sensor Input

Contact Buhler Versatile Inc (BVI) Service Center

 

 

# 2 Circuit – shorted high

 

 

 

 

 

F511

B

Auxiliary Pressure Sensor Input

Contact Buhler Versatile Inc (BVI) Service Center

 

 

# 2 Circuit – shorted low

 

 

 

 

 

F512

B

Injector Metering Rail

Contact Buhler Versatile Inc (BVI) Service Center

 

 

#2 Pressure Sensor Circuit - shorted high

 

435/485/535