Section 3 - Operation
EIC - Calibration
Entering Wheel speed calibration (Mode 20)
A 100 meter (328 ft) track is required to perform wheel speed calibration.
1.Drive tractor to the start of the designated test area..
2.Stop the tractor 10 m before the start line..
3.Press and hold the SELECT button (1) on the Tractor Performance Monitor (TPM) display for 2 seconds until TPM displays “1”..
4.Touch the UP arrow button (2) until the TPM displays “20”..
5.Press and hold the SELECT button (1) on the TPM for 2 seconds until TPM displays “DIST CAL 0”..
6.Select a low gear and drive the tractor forward..
7.As the tractor crosses the “Start Line” touch the SELECT button (1) once.. The TPM will display “DIST CAL 1”
8.Continue driving until the tractor reaches the “Finish Line”..
| AREA | PTO RPM |
| DISTANCE | START |
|
| |
|
| STOP |
| CAL | SELECT |
SPEED | % SLIP | 1 |
|
| |
|
|
|
| AREA | PTO RPM |
| DISTANCE | START |
|
| |
|
| STOP |
|
| SELECT |
SPEED | % SLIP | 2 |
|
| |
| AREA | PTO RPM |
| DISTANCE | START |
|
| |
|
| STOP |
OFF |
|
|
DIST | CAL | SELECT |
|
| |
SPEED | % SLIP | 1 |
|
| |
|
| |
| AREA | PTO RPM |
| DISTANCE | START |
ON |
| |
| STOP | |
DIST | CAL | SELECT |
|
| |
SPEED | % SLIP | 1 |
|
| |
|
|