3-45 Section 3 - Operation

EIC - Calibration

9.As the tractor crosses the “Finish Line” touch the SELECT button (1) once.. The TPM will display “DIST CAL 2”..

10.Touch select button (1) again to save the calibration.. The TPM will display “DIST CAL 3”..

11.Touch start/stop button (2) twice to exit mode 20..

12.Drive the tractor around and stop 10 m before the finish line..

Distance check

1.Touch the distance button (3) once.. If the TPM does not display “0 meters or feet” hold the start/stop button (2) for 2 seconds to clear the display..

2.Select a low gear and drive the tractor forward..

3.As the tractor crosses the “Finish Line” touch the start/stop (2) button once.. The TPM will begin accumulating distance traveled

4.Continue driving until the tractor reaches the “Start Line”..

5.As the tractor crosses the “Start Line” touch the start/stop (2) button once.. The TPM should show approximately 100 m (+/- 5 m), (328 ft (+/- 15 ft).. If not, re-run distance check..

 

AREA

PTO RPM

 

DISTANCE

START

ON

 

 

STOP

DIST

CAL

SELECT

 

 

SPEED

% SLIP

1

 

 

AD-11

 

AREA

PTO RPM

 

 

DISTANCE

START

 

 

 

 

 

 

STOP

 

DIST

CAL

SELECT

2

 

 

SPEED

% SLIP

 

1

 

 

 

AD-12

AREA PTO RPM

3

DISTANCE

 

 

STOP

 

 

METERS

SELECT

2

 

 

 

 

 

SPEED

% SLIP

 

 

AD-13

435/485/535