Appendix A Cisco CRS-1 4-Slot Line Card Chassis System Specifications

Cisco CRS-1 4-Slot Line Card Chassis Specifications

Table A-1 Cisco CRS-1 4-Slot Line Card Chassis Specifications (continued)

 

 

 

 

Chassis with all components

361 lb (163.7 kg)

 

 

 

 

installed (without exterior

 

 

 

 

 

 

cosmetic components and

 

 

 

 

 

 

packaging)

 

 

 

 

 

 

 

 

 

 

 

 

Cards and Modules Supported

4 modular services cards (MSCs)

 

 

 

 

 

4 physical layer interface modules (PLIMs)

 

 

 

 

 

or

 

 

 

 

 

4 shared port adapter (SPA) interface processors (SIPs), each of

 

 

 

 

 

which supports one or more SPAs

 

 

 

 

 

2 route processors (RPs)

 

 

 

 

 

4 switch fabric cards

 

 

 

 

 

1 fan tray

 

 

 

 

 

 

 

 

 

 

 

Power Shelves

 

 

 

 

 

 

AC power shelf

Supports four AC-to-DC rectifiers

 

 

 

 

 

 

 

 

 

 

DC power shelf

Supports four DC power supplies

 

 

 

 

 

 

 

 

 

 

Maximum Power Consumption

Total input power

 

 

 

 

Maximum AC input power

4185 W (assuming 92% efficiency)

 

 

 

 

Maximum DC input power

4278 W (assuming 90% efficiency)

 

 

 

 

 

 

 

 

 

 

 

DC power lug torque ranges

 

 

 

 

 

 

 

 

 

 

 

 

Minimum torque

20 in-lb (2.2 N-m)

 

 

 

 

Maximum torque

30 in-lb (3.3 N-m)

 

 

 

 

 

 

 

 

 

 

 

Power Redundancy

 

 

 

 

 

 

AC

1:1—Requires two independent AC sources

 

 

 

 

DC

We recommend two independent -48 VDC power sources

 

 

 

 

 

 

 

 

 

 

AC Input Power

2W+PE (2 wire + protective earthing1)

 

 

 

 

Nominal input voltage

200 to 240 VAC

 

 

 

 

 

(range: 180 to 264 VAC)

 

 

 

 

Nominal line frequency

50 or 60 Hz

 

 

 

 

 

(range: 47 to 63 Hz)

 

 

 

 

Recommended AC service

20 A (per AC rectifier)

 

 

 

 

 

 

 

 

 

 

 

DC Input Power

 

 

 

 

 

 

 

 

 

 

 

 

Nominal input voltage

Supports -48 VDC and -60 VDC systems (range: –40 to –72 VDC)

 

 

 

 

 

 

 

 

 

 

Input line current

50-A maximum at –48 VDC

 

 

 

 

 

40-A maximum at –60 VDC

 

 

 

 

 

 

 

 

 

 

Inrush current

60-A peak at 75 VDC

 

 

 

 

 

(maximum for 1 ms)

 

 

 

 

 

 

 

 

 

 

Chassis Cooling

1 fan tray, pull configuration

 

 

 

 

Chassis airflow

Up to 880 cubic ft (24,919 liters) per minute

 

 

 

 

Power shelf airflow

60 cubic ft (1699 liters) per minute

 

 

 

 

 

 

 

 

 