Chapter 4 Installing and Removing SFCs, RPs, MSCs, PLIMs, and Associated Components
How to Install or Remove a Modular Services Card
Verifying the Installation of an MSC
This section describes how to verify that an MSC has been properly installed. (Figure
Figure 4-24 CRS-MSC Front Panel
1 | 2 | 149967 |
|
Figure 4-25 CRS-MSC-B Front Panel
SN
*88052A*
1
2
CLEI
PIDVID
B1
BAL
280228
1
Status LED
2
Alphanumeric LEDs
Understanding the LEDs
Alphanumeric LEDs
At one end of the faceplate, near an ejector lever, an MSC has two
Note It is normal for some displayed messages to appear too briefly in the LED display to be read.
Status LEDs
Use the status LEDs, located on the MSC faceplate, to verify the correct installation of the MSC:
•When the card is properly installed, the Status LED turns green. If this LED is off, verify that the card is installed correctly.
•When the Status LED is blinking yellow, a problem exists on the board.
•When the Status LED is off, the board state is unknown. Verify that there is power to the board by looking at the indicators on the power module.