POST Error Messages continued

CodeMeaning

1766 Slot x Drive Array requires System ROM Upgrade.

Run Systems ROMPaq Utility

(RESUME = F1 KEY)

1767 Slot x Drive Array Option ROM is not Programmed Correctly or may Conflict with the Memory Address Range of an ISA Card.

Check the Memory Address Configuration of installed ISA Card(s) or

Run Options ROMPaq Utility to attempt

SMART-2/E Option ROM Reprogramming.

(RESUME = F1 KEY)

1768 Slot x Drive Array - Resuming logical drive expansion process

I-5

Recommended Action

Run the latest version of Systems ROMPaq. See Chapter 3 for details.

Check the Memory Address Range of any ISA cards that may be installed, and verify that they do not conflict with the address of the SMART- 2/E Option ROM as shown in the System Configuration Utility. If there is no conflict, run Options ROMPaq and attempt to reprogram the SMART-2/E Option ROM as described in the section, “Running Option ROMPaq,” in Chapter 3.

No action is required. This message appears whenever a controller resets or apower cycle occurs while array expansion is in progress.

continued

Compaq Smart Array 3200 Controller Reference Guide