![](/images/new-backgrounds/1268998/26899883x1.webp)
4-4 Running the System Configuration Utility
Configuring the Controller
The steps in this section include editing Controller Order and Online Recovery Server Status parameters. To make the correct selections, the parameters are discussed below.
Controller Order
Select the order in which you want this Smart Array 3200 Controller to be recognized. All hard disk controllers, including the integrated controller on the system board, must be assigned a unique order number.
First | The primary disk controller that contains the boot disk. The first disk |
| drive on this controller is the one the server will boot from. |
Second | The second disk controller. |
| . |
| . |
| . |
Fifteenth | The fifteenth disk controller. |
When installing a Smart Array 3200 Controller, you must determine if the boot disk is to be handled by a Smart Array 3200 Controller or the integrated SCSI controller. If this Smart Array 3200 Controller will be the primary controller, choose First; a Configuration Changes screen appears, indicating that if you accept this change the integrated SCSI controller will be changed automatically to Second. Press Enter to accept these changes.
If you want the order of the integrated SCSI controller to be something other than Second, scroll (usually down) to the Embedded Compaq Integrated Controller and set the Controller Order manually.