Compaq 3200 manual 6-11, Return to the INSTALL.NLM Disk Options menu

Models: 3200

1 211
Download 211 pages 41.29 Kb
Page 93
Image 93
6-11

6-11

6.Insert the replacement physical drive in the drive bay where the failed drive was located. The physical drive must be of the same capacity as the failed drive. Be sure that all cable connections are secure.

For replacements in a ProLiant server or storage system, after you secure the drive in the bay, the LEDs on the drive each light once in an alternating pattern to indicate that the connection was successful. The Online LED turns green, indicating that the controller has recognized and successfully initialized the replacement drive. If the Online LED does not light after a few minutes, verify that you added the new drive in the same slot as the failed drive and that the drive capacity is the same as the failed drive.

7.Activate the replaced device. Use the MONITOR.NLM Disk Information option to select the device. Some versions of NetWare will cause a “device activate” to occur automatically when this option is chosen. Other versions of NetWare require manual activation of the device by changing the operating status to active. If reactivation of the failed logical drive is successful, the driver sends a console alert.

8.Use the INSTALL.NLM option Change Hot Fix (look at the information provided about the mirrored drive, not the failed drive) to determine the number of Hot Fix Redirection blocks set up for this partition. Refer to the section “Using CPQDAOPT on NetWare Servers,” in Chapter 5 for more information about optimizing the performance on NetWare 3.12 servers.

9.Use the INSTALL.NLM to delete and create the partition on the repaired logical drive.

NOTE: Although the logical drive may have a valid partition table, the data on this logical drive is no longer valid. Some data may appear valid because the failed physical drive was only a portion of the arrayed logical drive. However, there is a hole in the logical drive data at this point. Delete any old, invalid data and create a new partition on the logical drive.

10.Return to the INSTALL.NLM Disk Options menu.

NOTE: If you are not running intraNetWare SFTIII or NetWare 4.x, you might be able to skip to Step 11.

Use the Mirroring selection to locate the Out of Sync partition. The device number for the Out of Sync partition should match the previously failed device number. Select the Out of Sync partition.

Compaq Smart Array 3200 Controller Reference Guide

Page 93
Image 93
Compaq 3200 manual 6-11, Return to the INSTALL.NLM Disk Options menu