Compaq 3200 manual POST Error Messages continued, CodeMeaning, Recommended Action

Models: 3200

1 211
Download 211 pages 41.29 Kb
Page 189
Image 189
Manual background

POST Error Messages continued

CodeMeaning

1724 Slot x Drive Array - Physical Drive Position Change(S) Detected - Logical drive configuration has automatically been updated.

1726 Slot x Drive Array - Array Accelerator Memory Size Change Detected.

I-3

Recommended Action

This message indicates that logical drive configuration has been updated automatically following physical drive position changes. Press F1 to resume.

This message indicates that the array accelerator configuration has been updated automatically due to replacement of the Array Accelerator (or controller) with one of them having a different memory size. Press F1 to resume.

1727 Slot x Drive Array - New Logical Drive(s) Attachment Detected. If more than 32 logical drives, this message will be followed by: Auto-configuration failed: Too many logical drives.

This message indicates that the controller has detected an additional array of drives that was attached when the power was off. The logical drive configuration information has been updated to add the new logical drives. The maximum number of logical drives supported is 32-additional logical drives will not be added to the configuration. Press F1 to resume.

continued

Compaq Smart Array 3200 Controller Reference Guide

Page 189
Image 189
Compaq 3200 manual POST Error Messages continued, CodeMeaning, Recommended Action