Microsoft Windows 2003 [x86]
No. Host System Operating
System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
203 Dell PowerEdge: 1800, 1850 Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP27,
R27, SP1, SP2;
Microsoft
Windows 2003
[x86] Standard
Edition: R2 SP27,
R27, SP1, SP2
PCI,
PCI−X QLogic: QLA210−E−SP5, 8, 17, 34, 69,
QLA2340−E−SP2, 8, 17, 32, 33 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 26 See31
204 Unisys: ES3220, ES3220L Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP27,
R27, SP1, SP2;
Microsoft
Windows 2003
[x86] Standard
Edition: R2 SP27,
R27, SP1, SP2
PCI,
PCI−X Unisys: FCH7430131−PCE (LPe1150)2,
22, 23, 24, 29, 71, FCH7430231−PCE
(LPe11002)2, 22, 23, 24, 29, 71,
FCH752313−PCX (LP1050)22, 23, 27, 29,
71
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
205 Dell PowerEdge: 1550, 2450, 2500, 255037,
4400, 6350, 6400, 645061, 8450 Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP27,
SP2
PCI Emulex LP1050−E2, 6, 15, 23, 27, 28, 29 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 26 See30
206 HPQ Proliant: 850039, DL320, DL360, DL360
(G2), DL380, DL380 (G2), DL380 (G3),
DL58039, ML350 (G2)39, ML35039, ML370
(G2)39, ML37039, ML530 (G2)39, ML530 (G3)39,
ML53039, ML57039, ML75039
Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP27,
SP2
PCI Emulex LP1050−E2, 6, 15, 27, 29 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 26 See30
207 HPQ Proliant: DL320, DL360 (G2), DL380 (G2),
DL380 (G3), DL58039, ML350 (G2)39, ML370
(G2)39, ML530 (G2)39, ML530 (G3)39, ML53039,
ML57039, ML75039
Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP27,
SP2
PCI Emulex LP1150−E2, 5, 6, 15, 29, 45 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 26 See30
208 HPQ Proliant: DL320, DL360, DL360 (G2),
DL58039, ML350 (G2)39, ML35039, ML370
(G2)39, ML37039, ML530 (G2)39, ML530 (G3)39,
ML53039, ML57039, ML75039
Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP27,
SP2
PCI Emulex LP982−E2, 6, 15, 27, 29 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 26 See30
209 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500,
255037, 4300, 4350, 4400, 6100, 6300, 6350,
6400, 6450, 8450
Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP27,
SP2
PCI Emulex: LP101−E2, 6, 15, 27, 29, 35,
LP982−E2, 6, 15, 23, 27, 28, 29 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 26 See30
210 HPQ Proliant: DL320, DL360, DL360 (G2),
DL58039, ML350 (G2)39, ML35039, ML370
(G2)39, ML37039, ML530 (G2)39, ML530 (G3)39,
ML53039, ML57039, ML75039;
IBM xSeries: x225, x230, x232, x240, x250,
x330, x335, x340 (4500R), x342, x350 (6000R),
x370
Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP27,
SP2
PCI QLogic QLA200−E−SP2, 8, 17, 34 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 26 See31
211 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500,
255037, 4300, 4350, 4400, 6100, 6300, 6350,
6400, 6450, 8450
Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP27,
SP2
PCI QLogic QLA200−E−SP2, 8, 34 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 26 See31
212 IBM xSeries: x225, x230, x232, x240, x250,
x330, x335, x340 (4500R), x342, x350 (6000R),
x370
Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP27,
SP2
PCI QLogic QLA210−E−SP5, 8, 17, 34 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 26 See31
213 HPQ Proliant: DL320, DL360, DL360 (G2),
DL58039, ML350 (G2)39, ML35039, ML370
(G2)39, ML37039, ML530 (G2)39, ML530 (G3)39,
ML53039, ML57039, ML75039
Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP27,
SP2
PCI QLogic QLA210−E−SP5, 8, 17, 34, 85 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 26 See31
214 Dell PowerEdge 1950 Microsoft
Windows 2003
[x86] Enterprise
Edition: R2 SP27,
SP2
PCI
Express Emulex LP1050−E2, 6, 15, 27, 28, 38 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y1, 26 See30
CLARiiON AX150
03/04/2009 152 CLARiiON AX150