Asianux AX [x86_64]
No. Host System Operating
System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
175 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL,
SR2500PAL;
Dell PowerEdge: 1950 III, 2900, 2900 III, 2950,
2950 III, 2970, 6950;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
HPQ Proliant: DL360 (G5), DL385 (G2), ML350
(G5)51, ML370 (G5)51, ML570 (G4)51;
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
Asianux
AX
[x86_64]
3.0 SP12,
3, 4
PCI
Express,
PCI−X
QLogic QLE2360−E−SP16, 37, 46 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
176 Acer Altos R720;
Anders & Rodewyk Ariane: 150, 155, 250;
BGM Elitas: SR520, SR720;
Compusys ProManaged: SR1500PAL,
SR2500PAL;
Digital Henge Revo: AS1500, AS1550, AS2500;
HCL Infiniti Global Line 2700 AO;
HPQ Proliant: DL 585 (G5), DL320 (G5), DL360
(G5), DL365, DL385 (G2), DL585 (G2), DL585
(G5), ML350 (G5)51, ML370 (G5)51, ML570 (G3)51,
ML570 (G4)51;
Intel: SE7525RP2, SR1500/S5000PAL,
SR2500/S5000PAL;
MPC NetFRAME: 1640, 1740, 2740;
MaxData Platinum: 1500 IR M6, 2200 IR M6;
Nanobay Nano AL2500;
Ockam Duo OSPAL−4200R;
Sun Sun Fire: X4100−M2, X4200−M2, X4600−M2;
Wipro NetPower: Z2105, Z2205;
Wortmann TERRA SERVER 6201
Asianux
AX
[x86_64]
3.0 SP12,
3, 4
PCI
Express,
PCI−X
QLogic QLE2460−E−SP16, 17 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
177 Dell PowerEdge: 1850, 1950 III, 2850, 2900 III,
2950 III, 2970 Asianux
AX
[x86_64]
3.0 SP12,
3, 4
PCI
Express,
PCI−X
QLogic QLE2462−E−SP6, 16, 44 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y10 See1
178 Dell PowerEdge: 1950 III, 2900, 2900 III, 2950,
2950 III, 2970, 6950 Asianux
AX
[x86_64]
3.0 SP12,
3, 4
PCI
Express,
PCI−X
QLogic: QLA2340−E−SP16, 33,
QLE2460−E−SP16, 17, 44 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
179 HPQ Proliant: DL360 (G5), DL385 (G2), DL585
(G2), DL585 (G5), ML350 (G5)51, ML370 (G5)51,
ML570 (G4)51;
IBM xSeries: x3550 (7978), x3650 (7979), x3655
(7943), x3655 (7985), x3755 (8877), x3800/x260
(8866), x3850/x366 (8864)
Asianux
AX
[x86_64]
3.0 SP12,
3, 4
PCI
Express,
PCI−X
QLogic: QLA2340−E−SP6, 16, 41,
QLA2342−E−SP6, 16, 41 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y5See1
180 Anders & Rodewyk Ariane 540;
BGM Elitas: SP520, SP720;
Compusys ProManaged: 5299XN, SC5400PSL;
Digital Henge Revo: LP5299, LS5400;
HCL Infiniti Global Line 2700: OW, SO, ST;
Intel: SC5299/SC5400/S5000PSLROMB,
SR2520/S5000VSA;
MPC NetFRAME 640;
Nanobay Nano: SL5299, SL5400;
Ockam Duo OSPSL−4200;
Wipro NetPower Z2503;
Wortmann TERRA SERVER: 6401, 6501
Asianux
AX
[x86_64]
3.0 SP12,
3, 4
PCI
Express,
PCI−X
QLogic: QLA2460−E−SP6, 16, 17,
QLE2460−E−SP6, 16, 17 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y18 See19
181 HPQ Proliant: DL360 (G5), DL385 (G2), ML350
(G5)51, ML370 (G5)51, ML570 (G4)51 Asianux
AX
[x86_64]
3.0 SP12,
3, 4
PCI
Express,
PCI−X
QLogic: QLE2360−E−SP6, 16, 37,
QLE2362−E−SP6, 16, 37 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y5See1
CLARiiON AX150
03/04/2009 53 CLARiiON AX150