VMware ESX Server
No. Host System Operating System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
282 HPQ Proliant: DL380 (G4),
DL385, DL585, ML370 (G4)33 VMware ESX Server:
3.0.13, 4, 5, 6, 7, 8, 9, 10,
3.0.23, 4, 5, 6, 7, 8, 9, 10,
3.0.33, 4, 6, 7, 8, 9, 10,
3.05, 6, 7, 8, 9, 10, 40
PCI,
PCI−X QLogic QLA2460−E−SP12, 32, 43 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
283 Dell PowerEdge: 1850, 1950,
2800, 2850, 6800, 6850;
HPQ Proliant: DL380 (G4), DL580
(G3)33, ML370 (G4)33;
Hewlett Packard Proliant DL360:
(G4), (G4p)
VMware ESX Server:
3.0.13, 4, 5, 6, 7, 8, 9, 10,
3.04, 5, 6, 7, 8, 9, 10, 40
PCI
Express Emulex LPe1150−E1, 2, 11, 12 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
284 NEC Express 5800: 120Li,
120Rg−1, 120Ri−2, 140He,
140Rd−4
VMware ESX Server:
3.0.13, 4, 5, 6, 7, 8, 9, 10,
3.04, 5, 6, 7, 8, 9, 10, 40
PCI
Express,
PCI−X
NEC N8190−127 (LPe1150)2, 11, 45, 62 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
285 HPQ Proliant: DL380 (G5), DL580
(G4) VMware ESX Server:
3.0.13, 4, 5, 6, 7, 8, 9, 10,
3.04, 5, 6, 7, 8, 9, 10, 40
PCI, PCI
Express,
PCI−X
HPQ: A8002A/FC2142SR (LPe1150)1, 2, 11, 12,
AD167A/FC2143 (LP1150)1, 2, 11, 12 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
286 HPQ Proliant DL380: (G4), (G5);
HPQ Proliant DL580: (G3)33,
(G4);
HPQ Proliant ML370 (G4)33
VMware ESX Server:
3.0.13, 4, 5, 6, 7, 8, 9, 10,
3.05, 6, 7, 8, 9, 10, 40
PCI, PCI
Express,
PCI−X
HPQ AE311A/FC1142SR (QLE2460)12, 32, 49 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
287 Dell PowerEdge: 1850, 1950,
1950 III, 2800, 2850, 2900 III,
2950 III, 2970, 6800, 6850, R805,
R900, R905;
Fujitsu Siemens Primergy RX300
S4;
HPQ Proliant: DL380 (G4), DL580
(G3)33, ML370 (G4)33;
Hewlett Packard Proliant DL360:
(G4), (G4p)
VMware ESX Server:
3.0.23, 4, 5, 6, 7, 8, 9, 10,
3.0.33, 4, 6, 7, 8, 9, 10
PCI
Express Emulex LPe1150−E1, 2, 11, 12 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
288 Dell PowerEdge 1950;
Sun Sun: Blade Server Module
X6450, Fire X4140, Fire X4240,
Fire X4440
VMware ESX Server:
3.0.23, 4, 5, 6, 7, 8, 9, 10,
3.0.33, 4, 6, 7, 8, 9, 10
PCI
Express Emulex: LP1050−E2, 11, 23, LP982−E2, 11, 23, 34 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
289 IBM xSeries: x3455 (7984),
x3850M2 (7141)105 VMware ESX Server:
3.0.23, 4, 5, 6, 7, 8, 9, 10,
3.0.33, 4, 6, 7, 8, 9, 10
PCI
Express IBM: 39R6525 (QLE2460)12, 32, 49, 39R6527
(QLE2462)12, 32, 43 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
290 NEC Express 5800 140Rf−4 VMware ESX Server:
3.0.23, 4, 5, 6, 7, 8, 9, 10,
3.0.33, 4, 6, 7, 8, 9, 10
PCI
Express NEC: N8190−120 (LP1050)2, 11, 35, 61,
N8190−127 (LPe1150)2, 11, 45, 62 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
291 Fujitsu Siemens Primergy RX300
S3;
Sun Sun: Blade Server Module
X6450, Fire X4140, Fire X4240,
Fire X4440
VMware ESX Server:
3.0.23, 4, 5, 6, 7, 8, 9, 10,
3.0.33, 4, 6, 7, 8, 9, 10
PCI
Express QLogic QLA2340−E−SP38, 39, 43 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
292 Fujitsu Siemens Primergy RX300
S4;
IBM xSeries: x3455 (7984),
x3850M2 (7141)105
VMware ESX Server:
3.0.23, 4, 5, 6, 7, 8, 9, 10,
3.0.33, 4, 6, 7, 8, 9, 10
PCI
Express QLogic QLE2460−E−SP12, 32, 43 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
293 Dell PowerEdge: 1950 III, 2900
III, 2950 III, 2970, R805, R900,
R905
VMware ESX Server:
3.0.23, 4, 5, 6, 7, 8, 9, 10,
3.0.33, 4, 6, 7, 8, 9, 10
PCI
Express QLogic QLE2460−E−SP12, 32, 59, 90 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
294 Fujitsu Siemens Primergy RX300
S4 VMware ESX Server:
3.0.23, 4, 5, 6, 7, 8, 9, 10,
3.0.33, 4, 6, 7, 8, 9, 10
PCI
Express QLogic QLE2460−E−SP12, 32, 90 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
295 Dell PowerEdge: 2850, 6850;
HPQ Proliant: DL385 (G2), DL585
(G2), DL585 (G5);
IBM xSeries: x3550 (7978),
x3800/x260 (8866), x3850/x366
(8864)
VMware ESX Server:
3.0.23, 4, 5, 6, 7, 8, 9, 10,
3.0.33, 4, 6, 7, 8, 9, 10
PCI
Express,
PCI−X
Emulex LP10000ExDC−E2, 11, 12, 23 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
296 Dell PowerEdge: 1850, 1950 III,
2850, 2900, 2900 III, 2950, 2950
III, 2970, 6850, 6950;
HPQ Proliant: DL360 (G5), DL385
(G2), DL585 (G2), DL585 (G5),
ML370 (G5)33, ML570 (G4)33;
IBM xSeries: x336 (8837)71,
x3550 (7978), x3650 (7979),
x3755 (8877), x3800/x260 (8866),
x3850/x366 (8864);
NEC Express 5800 140He
VMware ESX Server:
3.0.23, 4, 5, 6, 7, 8, 9, 10,
3.0.33, 4, 6, 7, 8, 9, 10
PCI
Express,
PCI−X
Emulex LP1050−E2, 11, 23 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
297 Dell PowerEdge: 1850, 1950 III,
2850, 2900, 2900 III, 2950, 2950
III, 2970, 6850, 6950;
Fujitsu Siemens Primergy TX300
S3;
HPQ Proliant DL360 (G5);
IBM: eServer 326m (Model 7969),
xSeries x336 (8837)71, xSeries
x3550 (7978), xSeries x3655
(7985), xSeries x3755 (8877),
xSeries x3800/x260 (8866),
xSeries x3850/x366 (8864)
VMware ESX Server:
3.0.23, 4, 5, 6, 7, 8, 9, 10,
3.0.33, 4, 6, 7, 8, 9, 10
PCI
Express,
PCI−X
Emulex LP1050Ex−E2, 11, 12, 23 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
CLARiiON AX150
03/04/2009 878 CLARiiON AX150