VMware ESX Server
No. Host System Operating System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
173 Dell PowerEdge: 1750, 2600,
2650, 6650 VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X QLogic: QLA2310F−E−SP29, 39, 81,
QLA2340−E−SP29, 39, 52, QLA2342−E−SP29, 39,
52
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
174 Hewlett Packard Proliant DL360:
(G4), (G4p);
IBM xSeries x3950/x3950E/x460
(8878, 8879)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X QLogic: QLA2460−E−SP12, 29, 32,
QLA2462−E−SP12, 29, 32 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
175 IBM xSeries x3800/x260 (8865)65 VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X QLogic: QLE2360−E−SP12, 29, 81,
QLE2362−E−SP12, 29, 81 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
176 Sun Sun Fire: X4100, X4200 VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X Sun: SG−XPCI1FC−QF4 (QLA2460)29,
SG−XPCI2FC−QF4 (QLA2462)29 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
177 Unisys ES7000/one [Xeon] VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X Unisys: FCH7440131−PCX (LP1150)1, 26, 31, 77,
FCH7440231−PCX (LP11002)1, 26, 31, 77,
FCH752313−PCX (LP1050)2, 23, 26, 31,
FCH752323−PCX31
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y48
178 HPQ Proliant BL20p (G2) VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X20 HPQ Dual−port Fibre Channel Adapter for HP
Proliant BL20p G2 300874−B2122, 29 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
179 HPQ Proliant BL25p VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X20 HPQ Dual−port Fibre Channel Adapter for HP
Proliant BL25p/BL45p 381881−B2122, 29 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
180 HPQ Proliant: BL25p, BL35p VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X20 HPQ Emulex−based BL25/30/35/45p Fibre
Channel Mezzanine HBA − 394588−B212, 23, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
181 HPQ Proliant BL20p: (G3), (G4);
HPQ Proliant BL25p (G2)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI−X20 HPQ: Emulex−based BL20p G3 Fibre Channel
Mezzanine HBA − 394757−B212, 23, 26, HP
QLogic−based Fibre Channel Mezzanine HBA
for BL20p G3/BL20p G4 361426−B2122, 29
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
182 Fujitsu Siemens Primergy TX200:
S3, S4 VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI, PCI
Express,
PCI−X
Emulex LPe11000−E1, 2, 12, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
183 HPQ Proliant: DL380 (G5), DL580
(G4), DL580 (G5) VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI, PCI
Express,
PCI−X
Emulex: LP10000−E2, 23, 26, LP10000DC−E2,
23, 26, LP1050−E2, 23, 26, LP1050DC−E2, 23, 26,
LP1050Ex−E2, 12, 23, 26, LP8000−EMC26, 37, 42,
LP9002−E (LP9002L−E)2, 26, 37, LP9802−E2, 26,
35, 36, LP9802DC−E2, 23, 26, 34, LP982−E2, 23,
26, 34;
HPQ: A8002A/FC2142SR (LPe1150)1, 2, 12, 26,
A8003A/FC2242SR (LPe11002)1, 2, 12, 26,
AD167A/FC2143 (LP1150)1, 2, 12, 26,
AD168A/FC2243 (LP11002)1, 2, 12, 26,
FCA2214/281541−B21 (QLA2340)29, 38,
FCA2214DC/321835−B21 (QLA2342)29, 38;
QLogic: QLA2200F−EMC29, 41,
QLA2310F−E−SP29, 38, 39, QLA2340−E−SP29,
38, 39, QLA2342−E−SP29, 38, 39
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
184 HPQ Proliant DL580: (G4), (G5) VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI, PCI
Express,
PCI−X
Emulex: LP11000−E1, 2, 12, 26, 31, LP11002−E1,
2, 12, 26, 31, LP1150−E1, 2, 12, 26, 31;
HPQ: AB429A/FC1143 (QLA2460)12, 29, 31, 32,
AE369A/FC1243 (QLA2462)12, 29, 31, 32;
QLogic: QLA2460−E−SP12, 29, 31, 32,
QLA2462−E−SP12, 29, 31, 32
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
185 HPQ Proliant DL380: (G4), (G5) VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI, PCI
Express,
PCI−X
Emulex: LP11000−E1, 2, 12, 26, LP11002−E1, 2,
12, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
186 Fujitsu Siemens Primergy TX200:
S3, S4;
HPQ Proliant: DL380 (G5), DL580
(G4), DL580 (G5)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI, PCI
Express,
PCI−X
Emulex: LPe11002−E1, 2, 12, 26, LPe1150−E1, 2,
12, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
187 HPQ Proliant DL380: (G4), (G5);
HPQ Proliant DL580: (G3)33,
(G4), (G5);
HPQ Proliant ML370 (G4)33
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI, PCI
Express,
PCI−X
HPQ: AE311A/FC1142SR (QLE2460)12, 29, 32,
AE312A/FC1242SR (QLE2462)12, 29, 32 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
188 Fujitsu Siemens Primergy TX200
S4;
HPQ Proliant DL380: (G4), (G5);
HPQ Proliant DL580: (G3)33,
(G4), (G5);
HPQ Proliant ML370 (G4)33
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI, PCI
Express,
PCI−X
QLogic: QLE2460−E−SP12, 29, 32,
QLE2462−E−SP12, 29, 32, QLE2560−E−SP12, 29 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
189 HPQ Proliant: DL380 (G4), DL580
(G3)33 VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI,
PCI−X Emulex LP1050Ex−E2, 12, 23, 26 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
190 HPQ Proliant: DL380 (G4),
DL385, DL580 (G2)33, DL580
(G3)33, DL585, ML370 (G3)33;
IBM: eServer 325 (Model 8835),
xSeries x445 (8870)
VMware ESX Server
3.56, 7, 8, 9, 10, 28 PCI,
PCI−X Emulex LP8000−EMC26, 37, 42;
QLogic: QLA2200F−EMC29, 41,
QLA2310F−E−SP29, 38, 39
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y13, 14
CLARiiON AX150
03/04/2009 872 CLARiiON AX150