Microsoft Windows 2008 [x86]
No. Host System Operating
System Host Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
157 HPQ Proliant: DL385 (G5), DL585 (G5);
IBM xSeries x3655 (7943)
Microsoft
Windows
2008 [x86]:
Enterprise
Edition6,
Standard
Edition6
PCI
Express,
PCI−X
Emulex LP1150−E2, 4, 5, 7,
12, 15 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y17 See21
158 IBM xSeries x3850/x366 (8864) Microsoft
Windows
2008 [x86]:
Enterprise
Edition6,
Standard
Edition6
PCI
Express,
PCI−X
Emulex LP1150−E5, 12, 15,
22, 28 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y17 See21
159 HPQ Proliant DL385 (G5) Microsoft
Windows
2008 [x86]:
Enterprise
Edition6,
Standard
Edition6
PCI
Express,
PCI−X
Emulex: LP10000−E2, 4, 7,
12, 15, 19, LP10000−E2, 4, 7,
12, 19, LP10000DC−E2, 4, 7,
12, 15, 19, LP10000DC−E2,
4, 7, 12, 19
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y17, 25 See21
160 HPQ Proliant DL585 (G2);
Hewlett Packard Proliant DL360: (G4), (G4p) Microsoft
Windows
2008 [x86]:
Enterprise
Edition6,
Standard
Edition6
PCI
Express,
PCI−X
Emulex: LP10000−E2, 4, 7,
12, 15, 19, LP10000−E2, 4, 7,
12, 19, LP10000DC−E2, 4, 7,
12, 15, 19, LP10000DC−E2,
4, 7, 12, 19
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y17 See16
161 HPQ Proliant: DL320 (G5), DL360 (G5), DL365,
DL385 (G2), DL585 (G2), ML350 (G5)27, ML370
(G5)27, ML570 (G4)27
Microsoft
Windows
2008 [x86]:
Enterprise
Edition6,
Standard
Edition6
PCI
Express,
PCI−X
Emulex: LP10000−E2, 4, 7,
12, 15, 19, LP10000−E2, 4, 7,
12, 19, LP10000DC−E2, 4, 7,
12, 15, 19, LP10000DC−E2,
4, 7, 12, 19
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y17, 25 See16
162 Hewlett Packard Proliant ML350: (G4), (G4p);
Sun Sun Fire X4600−M287
Microsoft
Windows
2008 [x86]:
Enterprise
Edition6,
Standard
Edition6
PCI
Express,
PCI−X
Emulex: LP10000−E2, 4, 7,
12, 15, 19, LP10000DC−E2,
4, 7, 12, 15, 19
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
163 Hewlett Packard Proliant ML350: (G4), (G4p) Microsoft
Windows
2008 [x86]:
Enterprise
Edition6,
Standard
Edition6
PCI
Express,
PCI−X
Emulex: LP10000−E2, 4, 7,
12, 19, LP10000DC−E2, 4, 7,
12, 19
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
164 IBM xSeries: x3550 (7978), x3650 (7979), x3755
(8877), x3800/x260 (8866), x3850/x366 (8864) Microsoft
Windows
2008 [x86]:
Enterprise
Edition6,
Standard
Edition6
PCI
Express,
PCI−X
Emulex: LP10000−E15, 19,
22, 28, LP10000DC−E15, 19,
22, 28, LP1050−E15, 19, 22,
28, LP1050DC−E15, 19, 22,
28, LP9802−E19, 20, 22, 28,
LP9802DC−E19, 20, 22, 28,
LP982−E19, 20, 22, 28
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y17, 25 See21
165 Dell PowerEdge: 1900, 2900, 2950, 6950 Microsoft
Windows
2008 [x86]:
Enterprise
Edition6,
Standard
Edition6
PCI
Express,
PCI−X
Emulex: LP10000−E7, 15,
19, 22, 28, LP10000DC−E7,
15, 19, 22, 28, LP1050−E7, 15,
19, 22, 28, LP1050DC−E7, 15,
19, 22, 28, LP9802−E7, 19, 20,
22, 28, LP9802DC−E7, 19, 20,
22, 28, LP982−E7, 19, 20, 22,
28
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y17 See21
166 IBM xSeries: x3550 (7978), x3650 (7979), x3755
(8877), x3800/x260 (8866), x3850/x366 (8864) Microsoft
Windows
2008 [x86]:
Enterprise
Edition6,
Standard
Edition6
PCI
Express,
PCI−X
Emulex:
LP10000ExDC−E12, 15, 19,
22, 28, LP1050Ex−E12, 15,
19, 22, 28, LP11000−E5, 12,
15, 22, 28, LP11002−E5, 12,
15, 22, 28, LPe11000−E5, 12,
15, 22, 28, 55, LPe11002−E5,
12, 15, 22, 28, 55,
LPe1150−E5, 12, 15, 22, 28,
55;
IBM: 42C2069
(LPe11000)4, 5, 12, 15, 22,
42C2071 (LPe11002)4, 5,
12, 15, 22, 42D0405
(LP11000)4, 5, 12, 15, 22,
42D0407 (LP11002)4, 12, 15,
22, 43
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y17 See21
167 Dell PowerEdge: 1900, 1950 III, 2900, 2900 III,
2950, 2950 III, 2970, 6950 Microsoft
Windows
2008 [x86]:
Enterprise
Edition6,
Standard
Edition6
PCI
Express,
PCI−X
Emulex: LP10000ExDC−E7,
12, 15, 19, 22, 28,
LPe11002−E5, 7, 12, 15, 22,
28, LPe1150−E5, 7, 12, 15, 22,
28
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y17 See21
168 IBM xSeries x3655 (7943) Microsoft
Windows
2008 [x86]:
Enterprise
Edition6,
Standard
Edition6
PCI
Express,
PCI−X
Emulex: LP1050−E2, 4, 7, 15,
19, LP1050−E2, 4, 7, 19,
LP982−E2, 4, 7, 19, 20
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y17, 25 See21
CLARiiON AX150
03/04/2009 259 CLARiiON AX150