VMware ESX Server
No. Operating
System Host Bus Adapter Switch Luns/HBA Port
Sharing Storage
Array Comments
4 VMware ESX
Server 3i1Emulex: LP10000−E, LP10000DC−E,
LP10000ExDC−E, LP1050−E,
LP1050DC−E, LP1050Ex−E,
LP11000−E, LP11002−E, LP1150−E,
LPe11000−E, LPe1150−E,
LPe1250−E;
QLogic: QLA2340−E−SP,
QLA2342−E−SP, QLA2460−E−SP,
QLA2462−E−SP, QLE2360−E−SP,
QLE2362−E−SP, QLE2462−E−SP
Brocade: 200E, 205E, 207E, 4100, 48000, 4900, 5000,
7500;
EMC Connectrix: 3250−VL2E6, DS−220B,
DS−220B−FF−D8, DS−4100B, DS−4900B, DS−5000B,
DS−8B2−0DL, ED−48000B;
McDATA ES−43007;
QLogic SANBox: SB1404−10AJ−E, SB3050−08A−E
256 Y EMC
CLARiiON
AX150
5 VMware ESX
Server 3i1Emulex: LP10000−E, LP10000DC−E,
LP10000ExDC−E, LP1050DC−E,
LP1050Ex−E, LP11000−E,
LP11002−E, LP1150−E, LPe11000−E,
LPe1250−E;
QLogic: QLA2342−E−SP,
QLA2460−E−SP, QLA2462−E−SP,
QLE2360−E−SP, QLE2362−E−SP,
QLE2462−E−SP
EMC Connectrix: DS−4400M, DS−4700M;
McDATA: ES−4400, ES−4700
256 Y EMC
CLARiiON
AX150
6 VMware ESX
Server: 2.5.21, 5,
2.5.31, 5, 2.5.41,
5, 2.5.51, 5
Emulex: LP1050−E, LP1050Ex−E,
LP982−E;
IBM 24P0960 (QLA2340);
NEC N8190−120 (LP1050);
QLogic QLA2340−E−SP
Brocade: 200E, 205E, 207E, 4100, 48000, 4900, 5000,
7500;
EMC Connectrix: 3250−VL2E6, DS−220B,
DS−220B−FF−D8, DS−4100B, DS−4400M, DS−4700M,
DS−4900B, DS−5000B, DS−8B2−0DL, ED−48000B;
McDATA: ES−43007, ES−4400, ES−4700;
QLogic SANBox: SB1404−10AJ−E, SB3050−08A−E
128 Y EMC
CLARiiON
AX150
See4
7 VMware ESX
Server: 2.5.21, 5,
2.5.31, 5, 2.5.41,
5, 2.5.51, 5
HPQ Dual−port Fibre Channel Adapter
for HP Proliant: BL20p G2
300874−B21, BL25p/BL45p
381881−B21, BL30p/BL35p
354054−B21;
HPQ HP QLogic−based Fibre Channel
Mezzanine HBA for BL20p G3/BL20p
G4 361426−B21
HPQ Proliant BL p−Class patch panel [FC Pass−through]
(306465−B21) 256 Y EMC
CLARiiON
AX150
See4
8 VMware ESX
Server: 2.5.21, 5,
2.5.31, 5, 2.5.41,
5, 2.5.51, 5
IBM HS20 FC Exp Card:
(13N2203/26R0836),
(13N2203/26R0836) for IBM eServer
LS20, (26K4841/26K4859),
(48P7061/26R0836)
IBM Brocade: Enterprise SAN Switch Module For IBM
BladeCenter Servers (90P0165/90P0164), Entry SAN
Switch Module For IBM BladeCenter Servers (26K5601);
IBM: McData 6−Port Switch Module For IBM BladeCenter
Servers (32R1790), Optical Passthrough Module For IBM
BladeCenter Servers (02R9080/02R9082), QLogic 2−Port
Switch Module For IBM BladeCenter Servers (48P7062),
QLogic 6−Port Switch Module For IBM BladeCenter
Servers (26K6477/26K6481)
256 Y EMC
CLARiiON
AX150
See4
9 VMware ESX
Server: 2.5.21, 5,
2.5.31, 5, 2.5.41,
5, 2.5.51, 5
QLogic QLE2360−E−SP Brocade: 200E, 205E, 207E, 4100, 48000, 4900, 5000,
7500;
EMC Connectrix: 3250−VL2E6, DS−220B,
DS−220B−FF−D8, DS−4100B, DS−4400M, DS−4700M,
DS−4900B, DS−5000B, DS−8B2−0DL, ED−48000B;
McDATA: ES−43007, ES−4400, ES−4700;
QLogic SANBox: SB1404−10AJ−E, SB3050−08A−E
128, 256 Y EMC
CLARiiON
AX150
See4
10 VMware ESX
Server: 2.5.21, 5,
2.5.31, 5, 2.5.41,
5, 2.5.51, 5,
3.0.11, 2, 3.0.2,
3.0.3, 3.01, 2
Dell 2342M Dell Brocade: 1/2Gb FC Switch Module (SW3014), 4Gb FC
Switch Module (SW4016)3;
Dell Optical Pass−thru Module (J6780)
256 Y EMC
CLARiiON
AX150
11 VMware ESX
Server: 2.5.21, 5,
2.5.31, 5, 2.5.51,
5, 3.0.11, 2, 3.0.2,
3.0.3, 3.01, 2
Dell QME2462 Dell Brocade: 1/2Gb FC Switch Module (SW3014), 4Gb FC
Switch Module (SW4016)3;
Dell Optical Pass−thru Module (J6780)
256 Y EMC
CLARiiON
AX150
12 VMware ESX
Server: 3.0.11, 2,
3.0.2, 3.0.3
Dell: 2342M, LPe1105−M, QME2462 Dell Brocade 4Gb FC Switch Module (SW4016) as Access
Gateway 256 Y EMC
CLARiiON
AX150
13 VMware ESX
Server: 3.0.11, 2,
3.0.2, 3.0.3
NEC N8403−018 (LPe1105) NEC: 12−Port 4GB FC Switch Module (N8406−019),
16−Port Pass−Through Module for NEC SigmaBlade−H
(N8406−017), 16−Port Pass−Through Module for NEC
SigmaBlade−M (N8406−012), 24−Port 4GB FC Switch
Module (N8406−020)
256 Y EMC
CLARiiON
AX150
14 VMware ESX
Server: 3.0.11, 2,
3.0.2, 3.0.3, 3.01,
2
Dell LPe1105−M Dell Brocade: 1/2Gb FC Switch Module (SW3014), 4Gb FC
Switch Module (SW4016)3;
Dell Optical Pass−thru Module (J6780)
256 Y EMC
CLARiiON
AX150
15 VMware ESX
Server: 3.0.11, 2,
3.0.2, 3.0.3, 3.01,
2
Emulex LP982−E;
HPQ: A8002A/FC2142SR (LPe1150),
AB429A/FC1143 (QLA2460),
AD167A/FC2143 (LP1150),
AD168A/FC2243 (LP11002),
AE311A/FC1142SR (QLE2460),
AE312A/FC1242SR (QLE2462),
AE369A/FC1243 (QLA2462);
IBM 24P0960 (QLA2340)
EMC Connectrix: DS−4400M, DS−4700M;
McDATA: ES−4400, ES−4700
256 Y EMC
CLARiiON
AX150
16 VMware ESX
Server: 3.0.11, 2,
3.0.2, 3.0.3, 3.01,
2
Emulex LP982−E;
QLogic QLA2340−E−SP Brocade: 200E, 205E, 207E, 4100, 48000, 4900, 5000,
7500;
EMC Connectrix: 3250−VL2E6, DS−220B,
DS−220B−FF−D8, DS−4100B, DS−4900B, DS−5000B,
DS−8B2−0DL, ED−48000B;
McDATA ES−43007;
QLogic SANBox: SB1404−10AJ−E, SB3050−08A−E
128 Y EMC
CLARiiON
AX150
CLARiiON AX150
03/04/2009 943 CLARiiON AX150